background image

EVAL AD5933-U1 

Preliminary Technical Data

 

Rev. PrA | Page 10 of 16 

To download the imaginary, real, phase and  magnitude data 
from the DFT of the response sweep, click 

Download 

Imaginary Data

Download Real Data

Download phase

 or 

Download Magnitude Data

. Choose a file name in the current 

directory and click 

Save File

 (Figure 16)  

05435-021

1: CHOOSE
DIRECTORY

2: CHOOSE
FILE NAME

3: SAVE THE FILE

4: CLOSE
PROGRAM FILE

 

Figure 16. 

This saves the sweep data to a data file located in the directory 
of you choice. You can access this file content by using Notepad 
or Microsoft Excel to plot the data. Each file contains a single 
column of data. Each data entry corresponds to each single 
sweep point so, if you program 511 point as the value for the 
number of increments, the array contains a single column of 
data with 511 data points, starting at the start frequency and 
ending at stop frequency value, which is determined by 

Start frequency 

+ (

number of increments

 × 

delta frequency

The

 impedance profile with frequency

 appears after the sweep 

finishes. This shows how the impedance of the network under 
analysis varies across the programmed frequency range. To view 
how the relative phase across the network under analysis varies, 
click 

relative phase vs. frequency

. The plot in Figure 17 

appears. Click 

Run plot

 to display the plot. 

The relative phase takes into account the phase introduced 
through the entire signal path, that is, the phase through the 
output amplifiers, transimpedance amplifiers, along with the 
phase through the impedance under analysis connected 
between VOUT and VIN (Pin 6 and Pin 5 of the AD5933). 

 

05435-023

PRESS THIS BUTTON
TO RUN THE PLOT

 

Figure 17. 

 

FREQUENTLY ASKED QUESTIONS 

Q: How can I confirm that the hardware has been correctly 
installed in my computer? 

A: Right-click 

My Computer 

and left-click 

Propertie

s. On the 

Hardware

 tab, click 

Device Manager

05435-013

 

Figure 18. 

Scroll to 

Universal Serial Bus Controllers

 and expand this 

directory root (Figure 19). When the AD5933 hardware is 
correctly installed, each time you plug the USB cable into the 
evaluation board, the items under the 

Universal Serial Bus 

Controllers

 root are refreshed. This indicates that the AD5933 

is present each time the evaluation board USB cable is plugged 
in correctly. It is subsequently refreshed when the USB cable is 

Содержание EVAL AD5933-U1

Страница 1: ...mbines an on board frequency generator with a 12 bit 1 MSPS ADC The frequency generator allows an unknown external impedance to be excited with a known frequency The response signal from the impedance...

Страница 2: ...uration and Function Descriptions 5 Getting Started 6 Setup Sequence Summary 6 Step 1 Install the Software 6 Step 2 Connect the USB Cable 7 Step 3 Verify the Links and Power Up The Evaluation Board 7...

Страница 3: ...AD5933 Analog Circuitry Input Supply AVDD REF is decoupled to the analog ground plane AGND J9 2 via standard 0 1 F and 10 F suppression capacitors J10 2 AGND Terminal Block Analog Ground Connection De...

Страница 4: ...an operational amplifier LK7 This link is inserted to connect the Tf2 OUT SMB connector to the inverting terminal of the transimpedance amplifier within the AD5933 This link is required to complete th...

Страница 5: ...edance amplifier Test impedance is connected between this pin and the VOUT pin 6 VOUT Output AC Excitation Signal Programmable frequency range 0 Hz to 50 kHz Test impedance is connected between this p...

Страница 6: ...aluation board software to run the sweep function See Step 4 Perform a Frequency Sweep STEP 1 INSTALL THE SOFTWARE Place the CD accompanying the evaluation board into the CD drive of the user computer...

Страница 7: ...not passed the Windows logo testing to verify compatibility with Windows XP This error appears because this is an evaluation setup installation and not meant to be used in a production environment Cli...

Страница 8: ...ace program is run it appears as shown in Figure 13 The figure shows the interface along with an impedance profile for a sweep across 15 pF ceramic capacitive impedance This section describes how to s...

Страница 9: ...this example choose capacitor only to measure the impedance sweep across a capacitor For this example enter 0 the Resistor Value box and 15E 12in the Capacitor Value box To program the sweep condition...

Страница 10: ...the impedance of the network under analysis varies across the programmed frequency range To view how the relative phase across the network under analysis varies click relative phase vs frequency The...

Страница 11: ...e Device Manager Expand Other devices Figure 22 05435 017 1 EXPAND THIS DIRECTORY 2 RIGHT CLICK ON THIS DEVICE Figure 22 The computer has not recognized the USB device that is the AD5933 evaluation bo...

Страница 12: ...15 14 13 12 11 10 9 T1 T2 T5 T6 R2 50 LK7 OP97 U1 OUT 6 7 4 2 3 VIN TRIM VOUT GND U4 ADR425 C32 0 1 F C31 10 F 2 5 6 4 CLK2 LK6 LK2 LK3 LK4 LK5 C25 10 F C26 0 1 F C30 10 F C28 0 1 F C2 10 F C24 0 1 F...

Страница 13: ...OE PA3 WU2 PA4 FIFOADR0 PA5 FIFOADR1 PA6 PKTEND PA7 FLO SLCS RDY0 SLRD RDY1 SLWR IFCLK RSVD AGND GND GND GND GND GND GND GND AVCC VCC VCC VCC VCC VCC VCC VCC VCC WP SCL SDA U2 24LC64 C22 0 1 F 3 3V 8...

Страница 14: ...8 ADP3300 3 3 8 7 1 IN1 2 6 3 SD GND OUT2 ERROR NR IN2 5 1 4 C16 0 1 F T1 T2 T3 T4 C15 0 1 F C14 10 F 3 3V D4 3 3V R24 1k Figure 26 05435 027 C12 10 F C11 0 1 F DVDD_5V DGND J2 2 J2 1 C35 10 F C36 0 1...

Страница 15: ...ve device Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection Although this product features proprietary ESD protection...

Страница 16: ...5933 U1 Preliminary Technical Data Rev PrA Page 16 of 16 NOTES 2005 Analog Devices Inc All rights reserved Trademarks and registered trademarks are the property of their respective owners EB05435 0 3...

Отзывы: