EV-ADF5904SD2Z User Guide
UG-791
QUICK START GUIDE
Follow these steps to quickly evaluate the
1. Connect the power supply to the
a. 5 V to Banana Connector P2
b. GND to Banana Connector P1
3. Connect the SDP-S motherboard to the PC and to the
4. Follow the hardware driver installation procedure.
5. Run the
software.
6. Select the
device and the USB board in the
Select Device and Connection tab of the software front
panel window (see Figure 2).
7. Check that the message SDP board connected appears at
the bottom left of the software window (see Figure 2).
8. Connect an ac-coupled RF source to LOIN SMA and
connect an ac-coupled RF source to one of the RXxIN
input SMAs.
9. In the Main Controls tab, click Initialize.
10. Connect the corresponding Rx baseband channel output to
an oscilloscope.
11. Measure the results.
Rev. 0 | Page 3 of 14