BATTERY PROTECTION FUNCTION EVALUATION 

All battery protection voltage and current threshold settings, 
hysteresis setting, and deglitch time is set up in the 

Battery 

Protection Setting

 section, under the 

Charge Control

 tab, 

shown in Figure 18. 

20

603

-018

 

Figure 18. GUI 

Charge Parameter Control

 Settings 

Ensure the EN_BATPRO bit, corresponding indicator located 
in the 

Charge Control

 tab (see Figure 11), is set to high and 

that the battery protection feature is enabled and lit up. 

206

03-

019

 

Figure 19. GUI 

Charger_Status1

 Settings 

For UV protection, set the ISOB voltage lower than the default 
2.5 V 

UV_DISCH, battery UV threshold

 value (see Figure 18). 

Next, check that the 

BAT_UV_STATUS

 (see Figure 19) status 

bit is set to high, the VSYS node voltage is shut down, and that 
the battery is isolated from the VSYS side. 

For overvoltage (OV) protection, set the battery simulator voltage 
higher than the default 4.3 V 

OV_CHG, charge OV threshold

 (see 

Figure 18) value. Then check that the 

BAT_OV_STATUS

 (see 

Figure 19) status bit set to high and that the VSYS node is 
isolated from the ISOB node. 

 

 

 

To enable the overdischarge current protection, set the VSYS 
load current (see Figure 17) at the system output to the default 

OC_DISCH, battery OC threshold

 value (see Figure 18). Next, 

check that the battery ISOB node is isolated from the VSYS 
side, and that the BAT_OC fault bit (see Figure 20) is set high 
(

BAT_OC

 lit up). 

20

603-

02

0

 

Figure 20. GUI 

Fault Status

 Settings 

To enable overcharge current protection, set the charge current 
higher than the default 

OC_CHG, charge OC threshold

 value 

(see Figure 18). Next, check that the charger has shut down and 
that the BAT_CHGOC fault bit (see Figure 20) is set high. 

BUCK REGULATOR EVALUATION 

Check that the EN1 jumper is set high on the evaluation board. 
Next, set the EN_BUCK bit high by clicking 

EN_BUCK

 in the 

GUI (see Figure 21). 

20603-

021

 

Figure 21. GUI 

Buck Setting

 in 

BUCK & BCKBST Control

 Tab 

In the 

Buck Setting

 section shown in Figure 21, keep the 

BUCK_MODE bit low (default) to select buck operation as 
hysteresis mode for low quiescent current. If the 
BUCK_MODE bit is set high, the buck regulator operates in 
force PWM (pulse-width modulation) mode for low noise 
using a lower noise power requirement. 

The default buck regulator output voltage is 1.2 V. Program the 
VOUT_BUCK bits (see Figure 21) to set the other output voltages 
in the 

VOUT_BUCK

 dropdown list. 

Содержание ADP5360

Страница 1: ...heet SOFTWARE NEEDED ADP5360 GUI Tool Software GENERAL DESCRIPTION This user guide describes the hardware and software used in the ADP5360CB EVALZ evaluation board and includes detailed schematics and...

Страница 2: ...ng Parameter Settings 6 Battery Fuel Gauge Settings 7 Buck and Buck Boost Settings 8 Direct Register Write and Read 9 Fuel Gauge Data Log 9 GUI Troubleshooting 10 Using the Evaluation Board 11 Powerin...

Страница 3: ...the LabVIEW runtime engine from the National Instruments website INSTALLING THE ADP5360 GUI SOFTWARE After installation it may be necessary to reboot the PC if the software is not working to complete...

Страница 4: ...ADP5360 GUI Tool Software the SDP drivers begins installing 2 A welcome window shown in Figure 6 appears Click Next to install the drivers 20603 006 Figure 6 SDP Drivers Setup Wizard 3 Click the Inst...

Страница 5: ...window shown in Figure 9 to check if USB SDP CABLEZ appears in the list 20603 009 Figure 9 Verify Driver Installation When the USB dongle is connected to a PC port that is different from the one used...

Страница 6: ...attery between ISOB and GND see Figure 17 2 The resistance in the thermistor THR input corresponds to a battery temperature between 10 C and 45 C If the THR resistance does correspond with the battery...

Страница 7: ...characteriza tion data then click the Program SoC Curve button to write all data to the ADP5360 The GUI then updates the Battery SoC Curve graph Other battery parameters in the GUI include the BAT_CA...

Страница 8: ...g section located on the bottom left of the GUI see Figure 12 To clear a fault if a fault occurs and any of the fault bits are high as indicated in the Fault Status section see Figure 12 verify that t...

Страница 9: ...gister read or write Enter the register address in the Register Address box Then either click the Read button to read the binary data or click the Write button to write the binary data Some registers...

Страница 10: ...015 Figure 15 GUI Error Report Window If the GUI shows the I2C Not Responding warning blinking in red in the top right corner of the window next to the STOP button see Figure 16 this may mean the I2 C...

Страница 11: ...per to the high side and click EN_BUCK in the Buck Setting section see Figure 12 to set the EN_BUCK bit high to enable the buck regulator Either set the EN2 jumper to the high side or set the EN_BUCKB...

Страница 12: ...the ISOB node level is close to the VTRM Termination Voltage value in the Charge Parameter Control box see Figure 10 The default value is 4 16 V The device is operating in constant voltage mode upon p...

Страница 13: ...from the ISOB node To enable the overdischarge current protection set the VSYS load current see Figure 17 at the system output to the default OC_DISCH battery OC threshold value see Figure 18 Next che...

Страница 14: ...oost Setting in BUCK BCKBST Control Tab Measure Load Regulation After the VOUT2 board terminal voltage reaches 5 V increase the load current at VOUT2 then check the voltage between the on board VOUT2...

Страница 15: ...ACE PGOOD RESET AND MR U1 ADP5360 VBUS F6 AGND1 F4 VSYS E6 VIN1 F2 SW1 E1 ISOB D6 VDD F5 BSNS C6 PGND1 F1 FB1 D1 VID1 D2 EN1 E2 STP C2 ILIM D5 ICS E5 VIN2 C1 SW2A B1 PGND2 A1 THR B6 ENCHG F3 ENSD B3 I...

Страница 16: ...Figure 25 Top Layer Recommended Layout for the ADP5360CB EVALZ Evaluation Board 20603 026 Figure 26 Second Layer Recommended Layout for the ADP5360CB EVALZ Evaluation Board 20603 027 Figure 27 Third L...

Страница 17: ...ADP5360CB EVALZ User Guide UG 1571 Rev 0 Page 17 of 18 20603 028 Figure 28 Bottom Layer Recommended Layout for the ADP5360CB EVALZ Evaluation Board...

Страница 18: ...DI Customer their employees affiliates and in house consultants The Evaluation Board is NOT sold to Customer all rights not expressly granted herein including ownership of the Evaluation Board are res...

Отзывы: