UG-500
Evaluation Board User Guide
Rev. 0 | Page 6 of 15
109
93-
0
1
4
Figure 4.
ADP5062
Evaluation Software GUI, Register R/W Tab
DIRECT REGISTER READ AND WRITE
It is possible to read and write the content of each register using
the
Register R/W
tab as indicated in the GUI. Click
READ
ALL
to update the contents of each register in the GUI. A single
register read or write can be done using the controls on the
right side of the
Register R/W
tab of the GUI. Type the I
2
C sub
address in the
Sub Address for READ and WRITE (0x00)
box,
and then press
ENTER
. Click
READ
to read the binary data, or
click
WRITE
to write the binary data. Type the binary data for
an I
2
C write, and then press
ENTER
. Note that some registers,
such as Register 0x00 and Register 0x01, are read only registers
and cannot be overwritten.