Evaluation Board User Guide
UG-500
Rev. 0 | Page 5 of 15
SETTING INTERRUPTS
The
ADP5062
includes several interrupt flags to inform the
system microcontroller of a status change in the corresponding
charger function. All interrupts are disabled by default, and
each interrupt can be separately enabled by issuing an I
2
C write
to Register 0x09.
The
Interrupts & Timers
tab (see Figure 3) in the GUI controls
the register settings. Register 0x0A is automatically read after
every 0.3 second timeout from the last user action involving the
GUI. When a certain interrupt is enabled, and there is a status
change in the corresponding function during charging, an
interrupt message is shown in the
Opr Control & Status
tab
(see Number 3 in Figure 2).
SETTING TIMERS
The default settings of the timers are shown in Figure 3. Changing
the timer settings can be done by clicking items in the
Timer
Settings (Write to Register 0x06)
box.
Register 0x09 controls the interrupt enables, and Register 0x06
controls the timer settings.
10
99
3
-01
3
1
2
Figure 3.
ADP5062
Evaluation Software GUI,
Interrupts & Timers