background image

Evaluation Board User Guide 

UG-002

 

Rev. 0 | Page 3 of 12 

EVALUATION BOARD HARDWARE 

The following instructions are for setting up the physical 
connections to the AD9551 evaluation board.  

SETTING UP THE POWER AND PC CONNECTIONS 

Set up the power and PC connections as follows: 

1.

 

Install the AD9551 evaluation software before connecting 
the evaluation board to your PC for the first time (see the 
Installing the Software section). Administrative privileges 
are required for installation. 

The AD9551 has the option of either being pin or register 
programmable. If the pin programmable option is desired, 
then no software is needed to control the part. However, it 
is recommended to install the software because if it is not 
installed, the computer will recognize the evaluation board 
as new hardware and attempt to install drivers. 

2.

 

Connect the USB cables to the evaluation board and the 
computer.  

The red LED labeled VBUS (CR2) on the AD9551 evaluation 
board should illuminate, and the USBSTAT LED should start 
blinking. If the USBSTAT LED is not blinking, ensure that 
the USB port on the PC is operational and that the USB cable 
is not damaged. 

3.

 

If the 

Found New Hardware Wizard

 automatically 

appears when the evaluation board is connected, select 

Install the software automatically

 and then click 

Next

.  

The 

Found New Hardware Wizard

 may appear twice, and 

a system restart may be required. 

Refer to the Evaluation Board Software section for details on 
running the AD9551 evaluation board software. 

SETTING UP THE SIGNAL CONNECTIONS 

After setting up the power and PC connections, use the 
following procedure to set up the signal connections: 

1.

 

Connect a signal generator to REF A SMA Connector J1.  

By default, the reference inputs on this evaluation board 
are ac-coupled and terminated 50 Ω to ground. An 
amplitude setting of 6 dBm is sufficient. 

2.

 

To connect a signal to REF B, connect the signal to SMA 
Connector J2.  

3.

 

Connect an oscilloscope, spectrum analyzer, or other lab 
equipment to any of the J3 to J6 SMA connectors on the 
upper right side of the board. The output connectors are 
single ended. A 50 Ω termination should be placed on all 
unused outputs. 

BYPASSING THE USB POWER SUPPLY 

The evaluation board can be configured to supply power to the 
AD9551 from an external power supply. Bypass the USB power 
supply as follows: 

1.

 

Remove the F2 ferrite bead (located on the backside of 
the board). 

2.

 

Connect a bench power supply to Pin 3.3V_1 of TB1 on 
the evaluation board. In addition, resistors on the evaluation 
board can be removed to further separate power supply 
connections to the AD9551. This is useful for measuring 
the AD9551 power consumption. Refer to the evaluation 
board schematics provided on the CD in the evaluation board 
kit (also available at 

www.analog.com

) for further details. 

 

Содержание AD9551

Страница 1: ...AD9551 evaluation board and includes detailed schematics and PCB layout artwork The AD9551 Revision D evaluation board is a compact easy to use platform for evaluating all features of the AD9551 multi...

Страница 2: ...d Software 4 Installing the Software 4 Using the Software 4 Guide to Programming the AD9551 5 Using an SPI Port 5 Using Dip Switches Manual Control 5 Using Software to Override Dip Switches Software C...

Страница 3: ...Next The Found New Hardware Wizard may appear twice and a system restart may be required Refer to the Evaluation Board Software section for details on running the AD9551 evaluation board software SET...

Страница 4: ...the evaluation board to the PC 2 Double click AD9551 Eval Software to run the AD9551 evaluation software A hardware installation window appears Depending on whether the evaluation board was found by...

Страница 5: ...s to low Note that S2 controls REF B If REF B is not used there is no need to change the S2 settings 4 Connect a signal generator to REF A SMA Connector J1 By default the reference inputs on this eval...

Страница 6: ...re outlined in this section From the main window the window for each functional block can be accessed by clicking the appropriate box in the main window When a subsection window closes after clicking...

Страница 7: ...u allows you to select which evaluation board the software controls see Figure 5 Click Refresh List to detect a recently connected evaluation board 08129 005 Figure 5 Select USB Device Window Selectin...

Страница 8: ...ion boxes in the main window have a checkbox labeled SPI If this box is selected the software allows serial port writes when conditions are changed in the corresponding subsection window When a subsec...

Страница 9: ...Input PLL DCXO Window Clicking Click for Details in the PLL DCXO box in the main window accesses the Input PLL DCXO window see Figure 12 08129 014 Figure 12 Input PLL DCXO Window PFD and Charge Pump W...

Страница 10: ...e OutSel Pin drop down box see Figure 18 in the main window controls the logic level on the OUTSEL pin of the AD9551 However this value can be overwritten by using the SPI control register 08129 019 F...

Страница 11: ...ioned for PC control 2 Verify that all five jumpers are in place on Connector P2 3 Set the positions of the S1 S2 and S3 dip switches to high 4 Click Calculate Device Settings in the main window of th...

Страница 12: ...ings that have not been loaded to the AD9551 evaluation board Click LOAD to load these settings to the evaluation board 4 Select 19 44MHz Mode in the Input PLL Mode box and then click OK ESD CAUTION 5...