FEATURES 

Simple power connection using USB connection and  

on-board LDO voltage regulators 

LDOs are easily bypassed for power measurements 
AC-coupled differential LVPECL SMA connectors 
SMA connectors for  

2 reference inputs 
2 PLL lock detect outputs 

Microsoft Windows®–based evaluation software  

with simple graphical user interface 

On-board PLL loop filter 
Easy access to digital I/O and diagnostic signals  

via I/O header 

Status LEDs for diagnostic signals 
USB computer interface 
Dip switch configurable for manual operation 
Software calculator provides flexibility, allowing programming 

almost any rational input/output frequency ratio 

 

GENERAL DESCRIPTION 

This user guide describes the hardware and software of the 
AD9551 evaluation board and includes detailed schematics and 
PCB layout artwork. The AD9551 Revision D evaluation board 
is a compact, easy to use platform for evaluating all features of the 
AD9551 multiservice clock generator.  

The AD9551 accepts one or two reference input signals to 
synthesize one or two output signals. The AD9551 uses a 
fractional-N PLL that precisely translates the reference frequency 
to the desired output frequency. The input receivers and output 
drivers provide both single-ended and differential operation. 
Reference conditioning and switchover circuitry internally 
synchronizes the two references so that if one reference fails, 
there is virtually no phase perturbation at the output. 

The AD9551 uses an external crystal and an internal DCXO to 
provide for holdover operation. If both references fail, the device 
maintains a steady output signal. This may mislead you to believe 
that the PLL is locked and the board is configured properly. A 
simple test is to move the input REF A or REF B clock a few kilo-
hertz and verify that the changes in output frequency track the input. 

 

DIGITAL PICTURE OF THE EVALUATION BOARD 

08

12

9-

00

1

 

Figure 1. 

AD9551 Evaluation Board, Revision D 

 

Содержание AD9551

Страница 1: ...AD9551 evaluation board and includes detailed schematics and PCB layout artwork The AD9551 Revision D evaluation board is a compact easy to use platform for evaluating all features of the AD9551 multi...

Страница 2: ...d Software 4 Installing the Software 4 Using the Software 4 Guide to Programming the AD9551 5 Using an SPI Port 5 Using Dip Switches Manual Control 5 Using Software to Override Dip Switches Software C...

Страница 3: ...Next The Found New Hardware Wizard may appear twice and a system restart may be required Refer to the Evaluation Board Software section for details on running the AD9551 evaluation board software SET...

Страница 4: ...the evaluation board to the PC 2 Double click AD9551 Eval Software to run the AD9551 evaluation software A hardware installation window appears Depending on whether the evaluation board was found by...

Страница 5: ...s to low Note that S2 controls REF B If REF B is not used there is no need to change the S2 settings 4 Connect a signal generator to REF A SMA Connector J1 By default the reference inputs on this eval...

Страница 6: ...re outlined in this section From the main window the window for each functional block can be accessed by clicking the appropriate box in the main window When a subsection window closes after clicking...

Страница 7: ...u allows you to select which evaluation board the software controls see Figure 5 Click Refresh List to detect a recently connected evaluation board 08129 005 Figure 5 Select USB Device Window Selectin...

Страница 8: ...ion boxes in the main window have a checkbox labeled SPI If this box is selected the software allows serial port writes when conditions are changed in the corresponding subsection window When a subsec...

Страница 9: ...Input PLL DCXO Window Clicking Click for Details in the PLL DCXO box in the main window accesses the Input PLL DCXO window see Figure 12 08129 014 Figure 12 Input PLL DCXO Window PFD and Charge Pump W...

Страница 10: ...e OutSel Pin drop down box see Figure 18 in the main window controls the logic level on the OUTSEL pin of the AD9551 However this value can be overwritten by using the SPI control register 08129 019 F...

Страница 11: ...ioned for PC control 2 Verify that all five jumpers are in place on Connector P2 3 Set the positions of the S1 S2 and S3 dip switches to high 4 Click Calculate Device Settings in the main window of th...

Страница 12: ...ings that have not been loaded to the AD9551 evaluation board Click LOAD to load these settings to the evaluation board 4 Select 19 44MHz Mode in the Input PLL Mode box and then click OK ESD CAUTION 5...