background image

Evaluation Board User Guide 

UG-169

 

Rev. 0 | Page 5 of 12 

EVALUATION BOARD SOFTWARE SETUP 

The instructions included in this section are for setting up the 
AD9523 evaluation board software.  

INSTALLING THE SOFTWARE 

Do not connect the evaluation board until the software 
installation is complete. To install the software, 

1.

 

Insert the AD9523 evaluation software CD-ROM into a PC 
CD disc drive. 

2.

 

Click 

My Computer

, and then double-click the 

AD9523EV CD

 icon.  

A window opens showing the contents of the CD divided 
into four sections: data sheet, layout, schematic, and software. 
The 

readme.txt

 file contains a description of the CD-

ROM contents, as well as any last minute instructions or 
information. 

3.

 

Double-click the 

Software

 folder, and then double-click 

AD9523Eval_Setup1.1.0.exe

. Follow the installation 

instructions. The default location for the evaluation 
software is 

C:\Program Files\Analog Devices\AD9523  

Eval Software\

4.

 

If there are any updates to the evaluation software on a 
supplemental CD or in the 

\Software\Updates

 folder, be 

sure to copy the new .exe file, as well as any setup files, to 
the default location. 

USING THE SOFTWARE 

After the evaluation software has been installed, you can run 
the software as follows: 

1.

 

Power up and connect the evaluation board to the PC. 

2.

 

Double-click 

AD9523 Eval Software

 to run the AD9523 

evaluation software.  

A hardware installation window appears. Depending on 
whether the evaluation board was found by the software, the 
text in this window is either light blue, indicating that the 
evaluation board was found, or red, indicating that the 
evaluation board was not found.  

3.

 

If the evaluation board was found, click in the window 
when the 

Evaluation Software Ready

 message appears.  

The main window of the evaluation board software appears. 
Proceed to the Software Operation section for more details 
about using the software. 

4.

 

If the evaluation board was not found, a dialog box appears 
that allows you to select an evaluation board to use while 
the software runs in standalone mode. Standalone mode is 
useful for viewing and generating register setup files. 

5.

 

If you connect the evaluation board while the evaluation 
board software is running, the window shown in Figure 4 
usually appears to prompt you to load the evaluation board 
with the evaluation board software settings or to read the 
current evaluation board settings into the software. 

09

17

1-

00

5

 

Figure 4. SYNC Evaluation Software Window 

6.

 

If the evaluation board was not automatically detected 
when it was connected, choose 

Select Evaluation Board

 

from the 

I/O

 menu, and then select 

Ezssp-0

Ezssp-1

, or 

Ezssp-2

 (see Figure 5).  

09

17

1-

00

6

 

Figure 5. Select USB Device Window 

 

           

Содержание AD9523

Страница 1: ...ity allowing programming of almost any rational input output frequency ratio GENERAL DESCRIPTION This user guide describes the hardware and software of the AD9523 and AD9524 evaluation boards and incl...

Страница 2: ...he Signal Connections 3 Bypassing the 6 V Wall Socket Power Supply 3 Using I2 C Serial Port Mode 4 Evaluation Board Software Setup 5 Installing the Software 5 Using the Software 5 Software Operation 6...

Страница 3: ...erminated 50 to ground An amplitude setting of 6 dBm is sufficient 2 Connect an oscilloscope spectrum analyzer or other lab equipment to any of the OUTx SMA connectors on the right side of the board T...

Страница 4: ...ss using Jumpers P5 and P6 see Figure 3 Note that setting P5 and P6 low is reserved for SPI mode 2 On the evaluation software select Configure Serial Port from the I O menu see the I O Menu section 3...

Страница 5: ...nd connect the evaluation board to the PC 2 Double click AD9523 Eval Software to run the AD9523 evaluation software A hardware installation window appears Depending on whether the evaluation board was...

Страница 6: ...r own window are outlined in this section From the main window the window for each functional block can be accessed by clicking the appropriate box When a subsection window closes after clicking OK th...

Страница 7: ...to select which evaluation board the software controls see Figure 7 Click Refresh List to detect a recently connected evaluation board 09171 008 Figure 7 Select USB Device Window Selecting Configure...

Страница 8: ...the evaluation software to write the register changes to the evaluation board automatically when they occur Selecting the Auto checkbox adjacent to the UPDATE box forces the evaluation software to is...

Страница 9: ...box from the main window see Figure 16 w configuration of PLL2 see Figure 17 g the CHARGE PUMP box i This window is most often used to vary the charge pump current PLL 2 CONTROLS Clicking t opens a w...

Страница 10: ...o vary the phase offset by changing the phase offset bits setting under the Divider Phase box in Figure 20 However for the new phase to take effect the SYNC signal must be toggled by clicking the SYNC...

Страница 11: ...PROM Control window is shown in Figure 25 is accessed by clicking the EEPROM button near the lower left corner of the main window To store the current register settings of the AD9523 to the EEPROM cli...

Страница 12: ...grants to Customer a free limited personal temporary non exclusive non sublicensable non transferable license to use the Evaluation Board FOR EVALUATION PURPOSES ONLY Customer understands and agrees t...

Отзывы: