![Anaheim Automation MBC25P11 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/anaheim-automation/mbc25p11/mbc25p11_user-manual_2939582015.webp)
15
#L010128
June 2002
Program Window
Speed Profile
Select speed profiles 1-4.
Send Accel/Decel
Send acceleration & deceleration parameter to the pulse generator. (1=fastest,
255=slowest)
Send Base Speed
Send base speed parameter to the pulse generator. (step/sec)
Send Max Speed
Send maximum speed parameter to the pulse generator. (step/sec)
Begin Motion
Motor will ramp up to maximum speed and keep moving until a limit switch is triggered.
Soft Limit
Motor will ramp down to base speed and continue running.
Hard Limit
Stop any motor motion.
Direction
Set direction to clockwise or counter-clockwise.
Reduced Current
Set reduced current on or off.
Microstep Resolu
-
tion
Set microstep resolution to divide by 1, 2, 4, or 8.
Ramp Down
Set ramp down option to yes or no.
Verify Parameters
Updates and displays controllers parameters and resets the error codes.