![AMX ViewStat Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/amx/viewstat/viewstat_instruction-manual_2939160046.webp)
Support Module Installation and Wiring
40
ViewStat Communicating Thermostat
Setting the Support Module DIP Switches
Both the VST-TTM and VST-TRH support modules contain a 6-position DIP switch (FIG. 30)
located on the circuit board to set the support modules address, mode (monitor/control), and the
temperature sensor source (T1/T2 or Onboard Sensor). The ViewStat displays the temperature
reading of whichever remote sensors are connected to support modules
in control mode
. When
multiple support modules are connected and in control mode, the ViewStat displays an average of
all incoming temperature readings. If all connected support modules are set to monitor mode, then
the ViewStat displays the temperature reading from the on-board sensor, and the temperature from
the remote sensor (or the average temperature if you’re using multiple sensors) is displayed as the
REMOTE temperature.
DIP switches 1 and 2: Address (1-4)
The following diagram shows how to set the top two address DIP switches. Each support module
must have its own address (1-4).
DIP switch 3: Temperature Sensor 1
Each support module has two sensors: Sensor 1 and Sensor 2. Determine whether you want the
Sensor 1 input to monitor or control temperature. If DIP switch number 3 is in the "off " position, it
will monitor the temperature.
If DIP switch 3 is set to the "on" position, it will use the Sensor 1 temperature to control the
thermostat. The sensor control temperature will be displayed on the thermostat. If multiple sensors
are daisy chained together, all of the sensors set to control will be averaged and the average
temperature will be displayed on the thermostat.
FIG. 30
VST-TTM or VST-TRH support module DIP switch
FIG. 31
Setting the top two address switches (switches 1 and 2)
1
2
3
4
5
6
ADDRESS
SPARE
T1/T2 (S1)
ADDRESS
MONITOR (S1)
MONITOR (S2)
ADDRESS
ADDRESS
CONTROL (S1)
CONTROL (S2)
SPARE
ONBOARD SENSOR
OFF
ON
ADDRESS 1
ADDRESS 2
ADDRESS 3
ADDRESS 4
If the support module is set to Address 1 and the Sensor 1 input is set to "monitor",
then the monitored temperature will be displayed as the remote temperature in the
lower left hand corner of the thermostat. Otherwise, the monitored value will only be
available through the home automation system.
Содержание ViewStat
Страница 1: ...instruction manual HVAC Controls ViewStat Communicating Thermostat...
Страница 6: ...iv ViewStat Communicating Thermostat Table of Contents...
Страница 12: ...Product Information 6 ViewStat Communicating Thermostat...
Страница 42: ...ViewStat Installation and Wiring 36 ViewStat Communicating Thermostat...
Страница 50: ...Support Module Installation and Wiring 44 ViewStat Communicating Thermostat...
Страница 74: ...Operating the Thermostat 68 ViewStat Communicating Thermostat...
Страница 75: ...Operating the Thermostat 69 ViewStat Communicating Thermostat...