Installation & Setup
13
Precis DSP Instruction Manual
Rack Installation
Precis DSP Distribution Matrix enclosures fit in a standard EIA 19 in. (48.26 cm) rack. Rack ears are
provided.
Required items for rack installation:
Enclosure
Rack ears & screws
Standard EIA 19 in. (48.26 cm) rack
Screwdriver
Screws that fit your rack for mounting the enclosure
Power cord
Surge-protector – highly recommended
PC or laptop computer with a null modem cable (for communication with the Precis DSP via
the RS-232 port, i.e., using the APGraphic EQ software for setup)
Installation Recommendations
Write the system’s serial number in an easily accessible location before installing the
Precis DSP in a rack. Viewed from the rear, the system’s serial number is located to the left on
the end of the enclosure.
Use earth-grounded power cords / system with the Precis DSP.
Attach all power cords to a single surge protector and/or an AC line conditioner.
Apply power to the Precis DSP enclosure before applying power to its source
and destination devices.
Installation Procedure
A flow chart showing the basic installation sequence is in FIG. 2. The procedure, which follows on
page 14, provides general steps with references to detailed information found in later sections of this
chapter. After the basic sequence is complete, see page 21 for fine tuning the audio with APGraphic EQ.
Caution:
To prevent overheating and airflow restriction, avoid placing high-heat producing
equipment directly above or below the enclosure. The system requires a minimum of one empty rack
unit above and below. Verify that the openings on the sides of the enclosure are not blocked and do
not have restricted air flow.
FIG. 2
Installation procedure