NXA-PDU-1508-8
2
NXA-PDU-1508-8 Power Distribution Unit (240V / 10A)
SAFETY INSTRUCTIONS
There are NO user serviceable parts within the NXA-PDU-1508-8.
DO NOT install or operate the NXA-PDU-1508-8 in an area where the ambient temperature
exceeds 40ºC (104ºF) or falls below 0ºC (32ºF).
DO NOT install or operate the NXA-PDU-1508-8 in an area in which the ambient relative humidity
exceeds 85% or an area that is prone to condensation.
DO NOT install or operate the NXA-PDU-1508-8 near water or in a location which may be prone
to water seepage, dripping or splashing.
DO NOT place objects containing liquids on the NXA-PDU-1508-8.
DO NOT operate the NXA-PDU-1508-8 externally.
NXA-PDU-1508-8 (240V) Specifications (Cont.)
RESET pushbutton:
The RESET pushbutton is a momentary breaker reset switch for the MASTER power
connection. Trippage of the RESET pushbutton causes a 0.5 second toggle on the
AxLink power line.
Press the RESET button to reset the PDU.
Rear Panel Components:
AXLINK POWER
connectors (8):
A 13.5VDC, 6.5A power supply is provided for AxLink power.
Eight 3.5mm (4-pin) AxLink captive-wire connectors provide power and data to up to
eight AxLink devices.
• AxLink power is switched in two banks of four outputs each.
BANK 1 contains AxLink connectors 1-4
BANK 2 contains AxLink connectors 5-8
• The PDU provides 6.5A total across all AxLink outputs.
MASTER connector
3.5mm Phoenix (4-pin) AxLink connector provides connectivity to the NetLinx Master
(always on).
TEMP (RTS) input:
3.5mm Phoenix (2 pin) connector provides connection to a Remote Temperature Sensor
(RTS).
CONFIG DIP Switch:
Eight-position DIP switch sets the AxLink device address.
International
Power Outlets (8):
Connector Type: IEC C-13, 10A
Maximum allowable current on a single high-voltage output: 8A
International
Power Inlet (1):
• Connector Type: IEC C-14, 10A (10A Input)
• Equipped with a safety fuse (see
Included
Accessories
)
Dimensions (HWD):
• 1 3/16" x 17" x 9 11/16" (2.97cm x 43.18cm x 24.54 cm)
• 1 RU
Weight:
9 lbs (4.08 kg)
Enclosure:
Steel, black powder coated finish.
Environmental:
• Operating Environment: 0°C - 40°C (32°F - 104°F)
• Storage Environment: -10°C - 60°C (14°C - 140°F)
• Relative Humidity: 5% - 85%, non-condensing
Certifications:
• CE
• CB Scheme
• SGS
• C-Tick
Included Accessories:
• ENV-VST-TSO Indoor/ Outdoor Temperature Sensor (FG2050-22)
• Removable rack ears
• Safety Fuse: 10A @ 240VAC
Note
: When replacing the fuse, use only a 10A 240V Slo-Blo fuse
Other AMX Equipment:
• ENV-VST-TSF Flush-Mount Indoor Temperature Sensor (FG2050-21)
• NEMA to C14 Power Cable (FG10-673-02)
Содержание NXA-PDU-1508-08
Страница 4: ...ii NXA PDU 1508 8 Power Distribution Unit 240V 10A Table of Contents ...
Страница 8: ...NXA PDU 1508 8 4 NXA PDU 1508 8 Power Distribution Unit 240V 10A ...
Страница 14: ...Installation 10 NXA PDU 1508 8 Power Distribution Unit 240V 10A ...
Страница 18: ...NetLinx Programming 14 NXA PDU 1508 8 Power Distribution Unit 240V 10A ...
Страница 19: ...NetLinx Programming 15 NXA PDU 1508 8 Power Distribution Unit 240V 10A ...