Installation
6
NXA-PDU-1508-8 Power Distribution Unit (240V / 10A)
AXLINK POWER Connectors 1-8
The 8 AxLink connectors (labelled “AXLINK POWER” are standard 4-pin AxLink captive-wire connectors
that provide data and power to up to 8 AxLink devices. (FIG. 6):
The AxLink device connectors are separated into two Banks:
BANK 1
includes AxLink connectors 1-4
BANK 2
contains connectors 5-8
The PDU provides switched power to banks 1 and 2.
MASTER Connector
The 4-pin captive-wire AxLink connector labelled “MASTER” provides AxLink connectivity between the
PDU and the NetLinx Master.
TEMP Connector
The PDU measures temperature with an accuracy of 1 degree C) via a remote temperature probe. Temperature
data is kept in non-volatile storage to retain across reboot. The 3.5mm Phoenix (2 pin) connector labelled
“TEMP” allows you to connect a Remote Temperature Sensor (RTS) as an optional accessory (FIG. 8).
The PDU comes with one ENV-VST-TSF Flush Mount Indoor Temperature Sensor (FG2050-21).
Connect either wire from the RTS to either pin on the TEMP connector.
FIG. 6
AxLink Connectors 1-8
The AxLink bus strip does not provide switching on AxLink data lines.
FIG. 7
MASTER (4-pin AxLink) and TEMP (2-pin) Connectors
This connector is always ON.
FIG. 8
TEMP Connector
PDU
RTS
The NXA-PDU-1508-8 is also compatible with the ENV-VST-TSO Outdoor
Temperature sensor (optional).
Содержание NXA-PDU-1508-08
Страница 4: ...ii NXA PDU 1508 8 Power Distribution Unit 240V 10A Table of Contents ...
Страница 8: ...NXA PDU 1508 8 4 NXA PDU 1508 8 Power Distribution Unit 240V 10A ...
Страница 14: ...Installation 10 NXA PDU 1508 8 Power Distribution Unit 240V 10A ...
Страница 18: ...NetLinx Programming 14 NXA PDU 1508 8 Power Distribution Unit 240V 10A ...
Страница 19: ...NetLinx Programming 15 NXA PDU 1508 8 Power Distribution Unit 240V 10A ...