background image

AMX Limited Warranty and Disclaimer

This Limited Warranty and Disclaimer extends only to products purchased directly from AMX or an AMX Authorized Partner which 
include AMX Dealers, Distributors, VIP’s or other AMX authorized entity.

AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of 
purchase, with the following exceptions:

Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay compo-
nents are warranted for a period of one (1) year.

Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year.

AMX lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long 
as the AMX lighting products are under warranty. AMX also guarantees the control of dimmable loads that are properly con-
nected to our lighting products. The dimming performance or quality there of is not guaranteed, impart due to the random combi-
nations of dimmers, lamps and ballasts or transformers.

AMX software is warranted for a period of ninety (90) days.

Batteries and incandescent lamps are not covered under the warranty.

AMX AutoPatch Epica, Modula, Modula Series4, Modula CatPro Series and 8Y-3000 product models will be free of defects in 
materials and manufacture at the time of sale and will remain in good working order for a period of three (3) years following the 
date of the original sales invoice from AMX. The three-year warranty period will be extended to the life of the product (Limited 
Lifetime Warranty) if the warranty card is filled out by the dealer and/or end user and returned to AMX so that AMX receives it 
within thirty (30) days of the installation of equipment but no later than six (6) months from original AMX sales invoice date. The 
life of the product extends until five (5) years after AMX ceases manufacturing the product model. The Limited Lifetime Warranty 
applies to products in their original installation only. If a product is moved to a different installation, the Limited Lifetime Warranty 
will no longer apply, and the product warranty will instead be the three (3) year Limited Warranty.

All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is obtained from the AMX 
RMA Department. The RMA number must be clearly marked on the outside of each box. The RMA is valid for a 30-day period. After 
the 30-day period the RMA will be cancelled. Any shipments received not consistent with the RMA, or after the RMA is cancelled, will 
be refused. AMX is not responsible for products returned without a valid RMA number.

AMX is not liable for any damages caused by its products or for the failure of its products to perform. This includes any lost profits, lost 
savings, incidental damages, or consequential damages. AMX is not liable for any claim made by a third party or by an AMX Autho-
rized Partner for a third party.

This Limited Warranty does not apply to (a) any AMX product that has been modified, altered or repaired by an unauthorized agent or 
improperly transported, stored, installed, used, or maintained; (b) damage caused by acts of nature, including flood, erosion, or earth-
quake; (c) damage caused by a sustained low or high voltage situation or by a low or high voltage disturbance, including brownouts, 
sags, spikes, or power outages; or (d) damage caused by war, vandalism, theft, depletion, or obsolescence.

This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim (including 
negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot be waived or amended by 
any person. This limitation of liability will be effective even if AMX or an authorized representative of AMX has been advised of the 
possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury.

Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of inci-
dental or consequential damages for consumer products. In such states, the limitation or exclusion of the Limited Warranty may not 
apply. This Limited Warranty gives the owner specific legal rights. The owner may also have other rights that vary from state to state. 
The owner is advised to consult applicable state laws for full determination of rights.

EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX MAKES NO OTHER WARRANTIES, EXPRESSED OR 
IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX 
EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED WARRANTIES THAT 
MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS LIMITED WARRANTY. EXCEPT AS OTHERWISE LIMITED 
BY APPLICABLE LAW, AMX RESERVES THE RIGHT TO MODIFY OR DISCONTINUE DESIGNS, SPECIFICATIONS, WARRAN-
TIES, PRICES, AND POLICIES WITHOUT NOTICE.

 

Содержание NetLinx NXI

Страница 1: ...Operation Reference Guide Product Category NXI NetLinx Integrated Controller No Master Last Revised 3 04 2013...

Страница 2: ...ked on the outside of each box The RMA is valid for a 30 day period After the 30 day period the RMA will be cancelled Any shipments received not consistent with the RMA or after the RMA is cancelled w...

Страница 3: ...fications 1 Relay Connections and Wiring 1 IR Serial Connections and Wiring 2 Input Output I O Connections and Wiring 2 Programming 1 Overview 1 Using the ID Button 1 Device Port System D P S 1 Progra...

Страница 4: ...programs 4 Linux Telnet client 4 LED Disable Enable SEND_COMMANDs 4 LED DIS 4 LED EN 4 ESC D 4 ESC H 4 RS232 422 485 Ports Channels 5 255 5 RS 232 422 485 SEND_COMMANDs 5 B9MOFF 5 B9MON 5 CHARD 5 CHA...

Страница 5: ...oller No Master Operation Reference Guide CP 9 CTOF 9 CTON 9 GET MODE 9 IROFF 10 POD 10 POF 10 PON 10 PTOF 10 PTON 11 SET IO LINK 11 SET MODE 11 SP 11 XCHM 12 XCH 12 ZAP HIGH 12 Input Output SEND_COMM...

Страница 6: ...4 NetLinx Integrated Controller No Master Operation Reference Guide Table of Contents...

Страница 7: ...he NXI is equipped with a removable faceplate that covers the front panel components FIG 1 Remove the faceplate to see the front panel containing groups of colored LED indicators that light when their...

Страница 8: ...N and POF commands Channel 255 feedback Power status when IOLink is set I O port Port 16 8 channel I O port for contact closure 0 5 VDC voltage sensing or interactive power sensing for IR ports Channe...

Страница 9: ...werFail used with PON and POF commands Channel 255 Power status when IOLink is set I O port Port 16 8 channel I O port for contact closure 0 5 VDC voltage sensing or interactive power sensing for IR p...

Страница 10: ...NXI NetLinx Integrated Controller 4 NetLinx Integrated Controller No Master Operation Reference Guide...

Страница 11: ...ntil you feel the rear edge of the card lightly snap into place 9 Re apply power and other connections as necessary Preparing connecting captive wires 1 Strip 0 25 inch of wire insulation off all wire...

Страница 12: ...high 3 5 5 VDC signal as a Release When used for outputs the I O port acts as a switch to GND and is rated at 200 mA 12 VDC The PWR pin 12VDC 200 mA is designed as a power output for the PCS2 or VSS2...

Страница 13: ...guage allows numbers in the range 0 32 767 Device 0 refers to the local master numbers greater than 32 767 are reserved NetLinx requires a Device Port System D P S specification This D P S triplet can...

Страница 14: ...that is defined in the DEFINE_DEVICE section of the program See ESC Pass Codes on page 3 for descriptions of the escape codes available in pass mode PING Tests network connectivity to and confirms th...

Страница 15: ...messages will be shown starting with the most recent SHOW NOTIFY Displays a list of devices that other systems have requested input from and the types of information needed Note that the local system...

Страница 16: ...e telnet RAFT If the code to go back to command mode is entered ALT 29 which is the character is not sent but telnet command mode is entered LED Disable Enable Send_Commands The following commands ena...

Страница 17: ...munication parameters to nine data bits one stop bit and locks in the baud rate CHARD Sets the delay time between transmitted characters in 100 microsecond increments Syntax SEND_COMMAND DEV CHARD Tim...

Страница 18: ...SEND_COMMAND DEV TSET BAUD Baud Parity Data Stop 485 DISABLE ENABLE HSOFF Disables hardware handshaking default Syntax SEND_COMMAND DEV HSOFF Example SEND_COMMAND RS232_1 HSOFF Disables hardware hand...

Страница 19: ...Syntax SEND_STRING DEV 27 17 Time Variable Time 1 255 in 100 microsecond increments Example SEND_STRING RS232_1 27 17 10 Sends a break character of 1 millisecond to the RS232_1 device 27 18 1 Sets th...

Страница 20: ...e Syntax SEND_STRING DEV 27 20 1 Example SEND_STRING RS232_1 27 20 1 Sets the RTS hardware handshaking output to High on the RS232_1 device IR Serial Ports Channels 00001 00229 IR commands 00229 00253...

Страница 21: ...times with the CTON and CTOF commands Syntax SEND_COMMAND DEV CP Number Variable Number 1 252 and 256 65 000 253 255 reserved Example SEND_COMMAND IR_1 CP 2 Clears the active buffered commands and pu...

Страница 22: ...d after receipt of this command You can only use the PON and POF commands when an IR device has a linked I O channel Syntax SEND_COMMAND DEV POF Example SEND_COMMAND IR_1 POF Sends power down IR comma...

Страница 23: ...ntax SEND_COMMAND DEV SET IO LINK Number Variable Number 1 8 set the I O channel to 0 to disable I O link settings Example SEND_COMMAND IR_1 SET IO LINK 1 Sets the IR_1 port link to I O channel 1 The...

Страница 24: ...4 enter SEND_COMMAND IR_1 XCH 343 Transmits the IR code as 3 4 3 enter Mode 2 Example x x x SEND_COMMAND IR_1 XCH 3 Transmits the IR code as 0 0 3 SEND_COMMAND IR_1 XCH 34 Transmits the IR code as 0...

Страница 25: ...nnel changes Pushes and Releases generate reports based on their active state Syntax SEND_COMMAND DEV GET INPUT CHAN Variable CHAN 1 8 Example SEND_COMMAND IO GET INPUT 1 Gets the I O port s active st...

Страница 26: ...tion knowledge In the ever changing AV industry continual education is key to success AMX University is dedicated to ensuring that you have the opportunity to gather the information and experience you...

Отзывы: