Programming

3

 NetLinx Integrated Controller (No Master) - Operation Reference Guide

ESC Pass Codes

There are 'escape' codes in the pass mode. These codes can switch the display mode or exit pass mode. The following 
'escape' codes are defined.

Program Port Commands (Cont.)

SET IP <D:P:S>

Prompts you to enter a Host Name, Type (DHCP or Fixed), IP address, Subnet Mask, and 
Gateway IP address. Enter Y (yes) to approve/store the information in the Master Card. 
Entering N (no) cancels the operation.

SET TIME

Prompts you to enter the new time for the Master Card.

When the time is set on the Master Card, the new time will be reflected on all devices in the 
system that have clocks (i.e. touch panels). By the same token, if you set the time on any 
system device, the new time will be reflected on the system’s Master, and all connected 
devices.

This will not update clocks on devices connected to another Master (in Master-to-Master 
systems)

SET URL <D:P:S>

Prompts you to enter the URL address and port number. Enter Y (yes) to approve/store the 
new addresses in the Master Card. Entering N (no) cancels the operation.

SHOW DEVICE <D:P:S>

Displays a list of all devices present on the bus.

SHOW LOG

Displays the log of messages stored in the Master's memory. The Master logs all internal 
messages and keeps the most recent messages. The log contains:

• Entries starting with first specified or most recent.

• Date, Day, and Time message was logged.

• Which object originated the message.

• The text of the message:

SHOW LOG [start] [end]

SHOW LOG ALL

• If 

start

 is not entered, the most recent will be first.

• If 

end

 is not entered, the last 20 messages will be shown.

• If 

ALL

 is entered, all stored messages will be shown, starting with the most recent.

SHOW NOTIFY

Displays a list of devices that other systems have requested input from and the types of 
information needed. Note that the local system number is 1061.

SHOW REMOTE

Displays a list of the devices this system requires input from and the types of information 
needed. When a NetLinx master connects to another NetLinx master, the newly connecting 
system has a device that the local system desires input from; the new system is told what 
information is desired from what device. Note the local system number is 1062.

SHOW ROUTE

Displays information about how this NetLinx master is connected to other NetLinx masters.

SHOW SYSTEM

Provides a list of all devices in all systems currently on-line. The system’s lists are either 
directly connected to this master (i.e. 1 hop away), or are referenced in the 
DEFINE_DEVICE section of the NetLinx program. 

You may provide the desired system number as a parameter to display only that system's 
information (e.g. SHOW SYSTEM 2001). The systems listed are shown in numerical order.

TCP LIST

Lists all active TCP/IP connections.

TIME

Displays the current time on the Master Card.

URL LIST <D:P:S>

Displays the list of URL addresses programmed in the Master Card. 

Escape Pass Codes

Command

Description

+ + ESC ESC

Exit Pass Mode: Typing a plus (shift =) followed by another plus followed by an ESC (the escape key) 
followed by another escape exits the pass mode. 

The Telnet session returns to "normal".

+ + ESC A

ASCII Display Mode: Typing a plus (shift =) followed by another plus followed by an ESC (the escape key) 
followed by an 'A' sets the display to ASCII mode. 

• Any ASCII characters received by the device will be displayed by their ASCII symbol. 

• Any non-ASCII characters will be displayed with a \ followed by two hex characters to indicate the 

characters hex value.

Содержание NetLinx NXI

Страница 1: ...Operation Reference Guide Product Category NXI NetLinx Integrated Controller No Master Last Revised 3 04 2013...

Страница 2: ...ked on the outside of each box The RMA is valid for a 30 day period After the 30 day period the RMA will be cancelled Any shipments received not consistent with the RMA or after the RMA is cancelled w...

Страница 3: ...fications 1 Relay Connections and Wiring 1 IR Serial Connections and Wiring 2 Input Output I O Connections and Wiring 2 Programming 1 Overview 1 Using the ID Button 1 Device Port System D P S 1 Progra...

Страница 4: ...programs 4 Linux Telnet client 4 LED Disable Enable SEND_COMMANDs 4 LED DIS 4 LED EN 4 ESC D 4 ESC H 4 RS232 422 485 Ports Channels 5 255 5 RS 232 422 485 SEND_COMMANDs 5 B9MOFF 5 B9MON 5 CHARD 5 CHA...

Страница 5: ...oller No Master Operation Reference Guide CP 9 CTOF 9 CTON 9 GET MODE 9 IROFF 10 POD 10 POF 10 PON 10 PTOF 10 PTON 11 SET IO LINK 11 SET MODE 11 SP 11 XCHM 12 XCH 12 ZAP HIGH 12 Input Output SEND_COMM...

Страница 6: ...4 NetLinx Integrated Controller No Master Operation Reference Guide Table of Contents...

Страница 7: ...he NXI is equipped with a removable faceplate that covers the front panel components FIG 1 Remove the faceplate to see the front panel containing groups of colored LED indicators that light when their...

Страница 8: ...N and POF commands Channel 255 feedback Power status when IOLink is set I O port Port 16 8 channel I O port for contact closure 0 5 VDC voltage sensing or interactive power sensing for IR ports Channe...

Страница 9: ...werFail used with PON and POF commands Channel 255 Power status when IOLink is set I O port Port 16 8 channel I O port for contact closure 0 5 VDC voltage sensing or interactive power sensing for IR p...

Страница 10: ...NXI NetLinx Integrated Controller 4 NetLinx Integrated Controller No Master Operation Reference Guide...

Страница 11: ...ntil you feel the rear edge of the card lightly snap into place 9 Re apply power and other connections as necessary Preparing connecting captive wires 1 Strip 0 25 inch of wire insulation off all wire...

Страница 12: ...high 3 5 5 VDC signal as a Release When used for outputs the I O port acts as a switch to GND and is rated at 200 mA 12 VDC The PWR pin 12VDC 200 mA is designed as a power output for the PCS2 or VSS2...

Страница 13: ...guage allows numbers in the range 0 32 767 Device 0 refers to the local master numbers greater than 32 767 are reserved NetLinx requires a Device Port System D P S specification This D P S triplet can...

Страница 14: ...that is defined in the DEFINE_DEVICE section of the program See ESC Pass Codes on page 3 for descriptions of the escape codes available in pass mode PING Tests network connectivity to and confirms th...

Страница 15: ...messages will be shown starting with the most recent SHOW NOTIFY Displays a list of devices that other systems have requested input from and the types of information needed Note that the local system...

Страница 16: ...e telnet RAFT If the code to go back to command mode is entered ALT 29 which is the character is not sent but telnet command mode is entered LED Disable Enable Send_Commands The following commands ena...

Страница 17: ...munication parameters to nine data bits one stop bit and locks in the baud rate CHARD Sets the delay time between transmitted characters in 100 microsecond increments Syntax SEND_COMMAND DEV CHARD Tim...

Страница 18: ...SEND_COMMAND DEV TSET BAUD Baud Parity Data Stop 485 DISABLE ENABLE HSOFF Disables hardware handshaking default Syntax SEND_COMMAND DEV HSOFF Example SEND_COMMAND RS232_1 HSOFF Disables hardware hand...

Страница 19: ...Syntax SEND_STRING DEV 27 17 Time Variable Time 1 255 in 100 microsecond increments Example SEND_STRING RS232_1 27 17 10 Sends a break character of 1 millisecond to the RS232_1 device 27 18 1 Sets th...

Страница 20: ...e Syntax SEND_STRING DEV 27 20 1 Example SEND_STRING RS232_1 27 20 1 Sets the RTS hardware handshaking output to High on the RS232_1 device IR Serial Ports Channels 00001 00229 IR commands 00229 00253...

Страница 21: ...times with the CTON and CTOF commands Syntax SEND_COMMAND DEV CP Number Variable Number 1 252 and 256 65 000 253 255 reserved Example SEND_COMMAND IR_1 CP 2 Clears the active buffered commands and pu...

Страница 22: ...d after receipt of this command You can only use the PON and POF commands when an IR device has a linked I O channel Syntax SEND_COMMAND DEV POF Example SEND_COMMAND IR_1 POF Sends power down IR comma...

Страница 23: ...ntax SEND_COMMAND DEV SET IO LINK Number Variable Number 1 8 set the I O channel to 0 to disable I O link settings Example SEND_COMMAND IR_1 SET IO LINK 1 Sets the IR_1 port link to I O channel 1 The...

Страница 24: ...4 enter SEND_COMMAND IR_1 XCH 343 Transmits the IR code as 3 4 3 enter Mode 2 Example x x x SEND_COMMAND IR_1 XCH 3 Transmits the IR code as 0 0 3 SEND_COMMAND IR_1 XCH 34 Transmits the IR code as 0...

Страница 25: ...nnel changes Pushes and Releases generate reports based on their active state Syntax SEND_COMMAND DEV GET INPUT CHAN Variable CHAN 1 8 Example SEND_COMMAND IO GET INPUT 1 Gets the I O port s active st...

Страница 26: ...tion knowledge In the ever changing AV industry continual education is key to success AMX University is dedicated to ensuring that you have the opportunity to gather the information and experience you...

Отзывы: