AMW 12_00
23
S
S
W
W
I
I
T
T
C
C
H
H
B
B
O
O
A
A
R
R
D
D
C
C
A
A
B
B
I
I
N
N
E
E
T
T
GENERAL
The switchboard cabinet is built-in the unit and located on removal of the left side panel against the large support of
the unit (view from the back).
Cables must always be lead into the bottom plate via the cable inlets. Ensure that the cables form a loop before
they enter the switchboard cabinet so that the lowest point of the cable sits below the cable openings of the
switchboard cabinet.
N
N
E
E
V
V
E
E
R
R
R
R
U
U
N
N
T
T
H
H
E
E
C
C
A
A
B
B
L
L
E
E
S
S
T
T
H
H
R
R
O
O
U
U
G
G
H
H
T
T
H
H
E
E
T
T
O
O
P
P
O
O
F
F
T
T
H
H
E
E
S
S
W
W
I
I
T
T
C
C
H
H
C
C
A
A
B
B
I
I
N
N
E
E
T
T
:
:
D
D
A
A
T
T
A
A
P
P
R
R
I
I
V
V
A
A
C
C
Y
Y
I
I
P
P
2
2
4
4
W
W
I
I
L
L
L
L
T
T
H
H
U
U
S
S
B
B
E
E
C
C
A
A
N
N
C
C
E
E
L
L
L
L
E
E
D
D
.
.
CONNECTION TERMINALS
The supply must be connected to the connection terminals as given on the diagram supplied.
A
A
T
T
T
T
E
E
N
N
T
T
I
I
O
O
N
N
N
N
E
E
V
V
E
E
R
R
C
C
O
O
N
N
N
N
E
E
C
C
T
T
2
2
3
3
0
0
V
V
A
A
C
C
T
T
O
O
T
T
H
H
E
E
L
L
O
O
W
W
V
V
O
O
L
L
T
T
A
A
G
G
E
E
B
B
O
O
A
A
R
R
D
D
T
T
E
E
R
R
M
M
I
I
N
N
A
A
L
L
S
S
.
.
T
T
H
H
I
I
S
S
W
W
I
I
L
L
L
L
I
I
N
N
E
E
V
V
I
I
T
T
A
A
B
B
L
L
Y
Y
L
L
E
E
A
A
D
D
T
T
O
O
A
A
F
F
A
A
U
U
L
L
T
T
I
I
N
N
T
T
H
H
E
E
E
E
L
L
E
E
C
C
T
T
R
R
O
O
N
N
I
I
C
C
C
C
O
O
N
N
T
T
R
R
O
O
L
L
A
A
N
N
D
D
T
T
R
R
A
A
N
N
S
S
F
F
O
O
R
R
M
M
E
E
R
R
.
.
C
C
O
O
N
N
N
N
E
E
C
C
T
T
I
I
O
O
N
N
S
S
M
M
U
U
S
S
T
T
B
B
E
E
M
M
A
A
D
D
E
E
A
A
C
C
C
C
O
O
R
R
D
D
I
I
N
N
G
G
T
T
O
O
T
T
H
H
E
E
R
R
U
U
L
L
E
E
S
S
O
O
F
F
T
T
H
H
E
E
A
A
R
R
T
T
,
,
I
I
N
N
A
A
C
C
C
C
O
O
R
R
D
D
A
A
N
N
C
C
E
E
W
W
I
I
T
T
H
H
T
T
H
H
E
E
C
C
E
E
S
S
T
T
A
A
N
N
D
D
A
A
R
R
D
D
S
S
A
A
N
N
D
D
E
E
X
X
E
E
C
C
U
U
T
T
E
E
D
D
B
B
Y
Y
A
A
R
R
E
E
G
G
I
I
S
S
T
T
E
E
R
R
E
E
D
D
I
I
N
N
S
S
T
T
A
A
L
L
L
L
E
E
R
R
T
T
H
H
E
E
Y
Y
A
A
R
R
E
E
T
T
H
H
E
E
R
R
E
E
F
F
O
O
R
R
E
E
N
N
E
E
V
V
E
E
R
R
O
O
U
U
R
R
R
R
E
E
S
S
P
P
O
O
N
N
S
S
I
I
B
B
I
I
L
L
I
I
T
T
Y
Y
.
.
COMPONENTS
All components used – except the circuit board (CDH product) - are standard electrical components.
They can be replaced easily thanks to their mounting on DIN rails.
Equivalent types must replace the relays used.
CONNECTION DIAGRAM
Each installation manual and each switchboard cabinet contains a specific connection diagram for the supply and a
connection diagram for options and controls
Diagrams are drawn in quiescent condition
All PCB are equipped with:
−
a fast glass fuse of 6,3 A for transformer supply and 230 V exits
−
a slow glass fuse of 200 mA (5 x 20 mm) on the secondary 24VDC transformer exit.
P
P
R
R
I
I
N
N
T
T
I
I
N
N
G
G
C
C
I
I
R
R
C
C
U
U
I
I
T
T
B
B
O
O
A
A
R
R
D
D
T
T
H
H
E
E
S
S
E
E
P
P
C
C
B
B
’
’
S
S
A
A
R
R
E
E
B
B
E
E
I
I
N
N
G
G
A
A
P
P
P
P
L
L
I
I
E
E
D
D
I
I
N
N
B
B
O
O
T
T
H
H
T
T
H
H
E
E
H
H
E
E
A
A
T
T
I
I
N
N
G
G
P
P
U
U
M
M
P
P
S
S
A
A
N
N
D
D
T
T
H
H
E
E
A
A
I
I
R
R
D
D
E
E
H
H
U
U
M
M
I
I
D
D
I
I
F
F
I
I
E
E
R
R
S
S
.
.
W
W
H
H
E
E
N
N
A
A
P
P
C
C
B
B
I
I
S
S
O
O
R
R
D
D
E
E
R
R
E
E
D
D
,
,
A
A
L
L
W
W
A
A
Y
Y
S
S
C
C
O
O
M
M
M
M
U
U
N
N
I
I
C
C
A
A
T
T
E
E
T
T
H
H
E
E
T
T
Y
Y
P
P
E
E
O
O
F
F
U
U
N
N
I
I
T
T
T
T
H
H
U
U
S
S
E
E
N
N
A
A
B
B
L
L
I
I
N
N
G
G
C
C
D
D
H
H
F
F
A
A
C
C
T
T
O
O
R
R
Y
Y
W
W
I
I
S
S
E
E
T
T
O
O
A
A
D
D
A
A
P
P
T
T
T
T
H
H
E
E
S
S
H
H
U
U
N
N
T
T
P
P
O
O
S
S
I
I
T
T
I
I
O
O
N
N
A
A
N
N
D
D
O
O
T
T
H
H
E
E
R
R
T
T
U
U
N
N
I
I
N
N
G
G
Содержание 100
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 18: ...14 AMW 12_00 I IN NS ST TA AL LL LA AT TI IO ON N E EX XA AM MP PL LE E ...