BOILERMATE

®

INDIRECT-FIRED WATER HEATERS

INSTALLATION & OPERATION INSTRUCTIONS

NOTE:

 A properly sized thermal 

expansion tank is required and should 

be installed in accordance with the 

product installation manual.

NOTE:

 The thermostat is adjusted to 

120°F when shipped from the factory.

READ CAREFULLY THE PRODUCT 

INSTALLATION & OPERATION INSTRUCTIONS.  

FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE 

MANUAL MAY RESULT IN SERIOUS OR FATAL INJURY AND/OR 

PROPERTY DAMAGE, AND WILL VOID THE PRODUCT WARRANTY.  

THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED 

PROFESSIONAL.  FOLLOW ALL APPLICABLE LOCAL AND STATE 

CODES AND REGULATIONS, IN THE ABSENCE OF SUCH CODES, 

FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING 

CODE AND NATIONAL ELECTRIC CODE, AS APPLICABLE.

This Product, like most Products under pressure, 

may over time corrode, weaken and burst or 

explode, causing serious or fatal injury, leaking or flooding and/or property 

damage. To minimize risk, a licensed professional must install and 

periodically inspect and service the Product. A drip pan connected to an 

adequate drain must be installed if leaking or flooding could cause property 

damage. Do not locate in an area where leaking could cause property 

damage to the area adjacent to the appliance or to lower floors of  

the structure.

CALIFORNIA PROPOSITION 65 WARNING!

 This product contains a 

chemical known by the State of California to cause cancer and to cause 

birth defects or other reproductive harm. (California Installer/Contractor - 

California law requires that this notice be given to consumer/end user of 

this product.) For more information: 

www.amtrol.com/prop65.html

A relief valve must be installed to prevent pressure in 

excess of local code requirement or maximum 

working pressure designated in the Product Manual, whichever is less. At 

least once every 3 years or if discharge is present, a licensed contractor 

should inspect the temperature and pressure relief valve and replace if 

corrosion is evident or the valve does not function.  

FAILURE TO INSPECT THIS VALVE AS DIRECTED COULD RESULT 

IN UNSAFE TEMPERATURE OR PRESSURE BUILD-UP WHICH 

CAN RESULT IN PRODUCT FAILURE, SERIOUS INJURY OR 

DEATH AND/OR SEVERE PROPERTY DAMAGE AND VOID THE  

PRODUCT WARRANTY.

Chlorine Aggressive Water:

 The water quality can 

significantly influence the life of this Product.  You 

should test for corrosive elements, acidity, total solids and other relevant 

contaminants, including chlorine and treat your water appropriately to 

insure satisfactory performance and prevent premature failure.

EXPLOSION HAZARD.

 The pressure of the heat 

transfer medium must be limited to a maximum of 30 

psig by an approved safety or relief valve on your boiler. The water heater 

pressure must be limited to 150 psig maximum by the installation of a 

temperature and pressure relief valve (included). The relief tube must be 

plumbed to a suitable drain per code. No reducing coupling or other 

restriction may be placed in this line.

The heat transfer medium must be water or other 

nontoxic fluid having a toxicity rating or class of 1, as 

listed in Clinical Toxicology of Commercial Products, 5th edition. The 

pressure of the heat transfer medium must be limited to 30 PSIG by an 

approved safety or relief valve.

Do not expose Product to freezing temperatures or 

temperatures in excess of the maximum rated 

operating temperature.

NOTE:

  Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present.  To avoid risk of personal 

injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a qualified professional immediately.  Current 

copies of the Product manual can be viewed at www.amtrol.com.  Use proper safety equipment when installing. 

THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER 

HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL 

INJURY AS WELL AS PROPERTY DAMAGE.

Models WH (Mechanical Control & Digital Control)

Models CH (Mechanical Control) 

Содержание BOILERMATE CH Series

Страница 1: ...elief valve and replace if corrosion is evident or the valve does not function FAILURE TO INSPECT THIS VALVE AS DIRECTED COULD RESULT IN UNSAFE TEMPERATURE OR PRESSURE BUILD UP WHICH CAN RESULT IN PRO...

Страница 2: ...upplier or local plumbing inspector for additional information Prevent pressure build up in any existing internal tankless coil Do not plug incoming or outgoing tappings in the internal tankless coil...

Страница 3: ...lost in the home in this priority mode Any demand for space heating is postponed until the water heater has reached its set temperature This delay in supplying the space heating zones is usually not n...

Страница 4: ...TOR WH Models CH Models Boiler Zone Returns Hot Water Supply Supply Cold Water Supply Therm X Trol Boiler Return Boiler Supply CWS Hot Water Supply Heat Trap EXTROL Expansion Tank and Air Purger Blowd...

Страница 5: ...a high pressure steam boiler greater than 15 psig Installation Boiler Piping AQUASTAT 3 Wire ZONE VALVE 24VAC END SWITCH TRANSFORMER L1 L2 AQUASTAT ZONE VALVE MOTOR 24VAC END SWITCH TRANSFORMER L1 L2...

Страница 6: ...ZONE ORANGE ORANGE WHITE BLACK BLUE BLUE VIOLET VIOLET POWER BURNER PUMP PRIORITY Multi Zone Control Using Post Purge L1 L2 TO BOILER X X BOILERMATE CIRCULATOR HEATING CIRCULATOR ORANGE ORANGE WHITE...

Страница 7: ...rtup Test Idle Heating Displayed briefly during intial powerup to test LED display segments Settings To adjust press and hold the SET button until the Temperature setting appears Cycle through setting...

Страница 8: ...nsufficient hot water 1 Demand exceeds capacity 2 Temperature too low 3 Boiler lacks output for simultaneous heat hot water 4 Fouled heat exchanger 5 Insufficient heat exchanger flow 1 Check sizing ba...

Страница 9: ...Control 2 2704R498 Mounting Panel Only Digital Control 3 2704R525 Mechanical Temperature Control 4 2704 093 Digital Temperature Control w Panel 5 940R101 Temperature Sensor Digital Control 2704 259 C...

Страница 10: ...10...

Страница 11: ...11...

Страница 12: ...2017 AMTROL Inc 9040 586 08 17 1400 Division Road West Warwick RI USA 02893 T 800 426 8765 F 800 293 1519 www amtrol com...

Отзывы: