Replacement Parts

Description

ID

WH Series

CH Series

Heat Exchanger Replacement, WH-41 Single Wall

1

2700-5000

-

Heat Exchanger Replacement, WH-41 Double Wall

2700-5002

-

Heat Exchanger Replacement, CH-41 Single Wall

-

2703R003

Heat Exchanger Replacement, CH-80 Double Wall

-

2702R002

Mounting Panel Only, Mechanical Control

2

2704R498

-

Mounting Panel Only, Digital Control

3

2704R525

-

Mechanical Temperature Control

4

2704-093

Digital Temperature Control w/Panel

5

940R101

-

Temperature Sensor, Digital Control

-

2704-259

-

Cold Water Inlet Tube, CH-41

6

-

2703R001

Cold Water Inlet Tube, CH-80

-

2702R001

T&P Safety Relief Valve

7

2700R1106

2700R1106

Top Outlet Union Tee

8

2700-635

-

To obtain replacement parts, contact the installer or place of purchase.

Technical support is available by calling AMTROL at (401) 535-1216.

1

1

2

3

4

5

8

7

Содержание BOILERMATE CH Series

Страница 1: ...elief valve and replace if corrosion is evident or the valve does not function FAILURE TO INSPECT THIS VALVE AS DIRECTED COULD RESULT IN UNSAFE TEMPERATURE OR PRESSURE BUILD UP WHICH CAN RESULT IN PRO...

Страница 2: ...upplier or local plumbing inspector for additional information Prevent pressure build up in any existing internal tankless coil Do not plug incoming or outgoing tappings in the internal tankless coil...

Страница 3: ...lost in the home in this priority mode Any demand for space heating is postponed until the water heater has reached its set temperature This delay in supplying the space heating zones is usually not n...

Страница 4: ...TOR WH Models CH Models Boiler Zone Returns Hot Water Supply Supply Cold Water Supply Therm X Trol Boiler Return Boiler Supply CWS Hot Water Supply Heat Trap EXTROL Expansion Tank and Air Purger Blowd...

Страница 5: ...a high pressure steam boiler greater than 15 psig Installation Boiler Piping AQUASTAT 3 Wire ZONE VALVE 24VAC END SWITCH TRANSFORMER L1 L2 AQUASTAT ZONE VALVE MOTOR 24VAC END SWITCH TRANSFORMER L1 L2...

Страница 6: ...ZONE ORANGE ORANGE WHITE BLACK BLUE BLUE VIOLET VIOLET POWER BURNER PUMP PRIORITY Multi Zone Control Using Post Purge L1 L2 TO BOILER X X BOILERMATE CIRCULATOR HEATING CIRCULATOR ORANGE ORANGE WHITE...

Страница 7: ...rtup Test Idle Heating Displayed briefly during intial powerup to test LED display segments Settings To adjust press and hold the SET button until the Temperature setting appears Cycle through setting...

Страница 8: ...nsufficient hot water 1 Demand exceeds capacity 2 Temperature too low 3 Boiler lacks output for simultaneous heat hot water 4 Fouled heat exchanger 5 Insufficient heat exchanger flow 1 Check sizing ba...

Страница 9: ...Control 2 2704R498 Mounting Panel Only Digital Control 3 2704R525 Mechanical Temperature Control 4 2704 093 Digital Temperature Control w Panel 5 940R101 Temperature Sensor Digital Control 2704 259 C...