The ACD-14 PLUS and ACD-14 TRMS-PLUS are digital clampmeters that measure both AC
and DC voltage, AC current, Resistance, Frequency, Continuity and Diode Test. Frequency
can be measured in the voltage and current modes.
WARNINGS AND PRECAUTIONS
Safety Information
• The ACD-14 PLUS Series Digital Clampmeters conform to EN61010-1:2001; EN61010-
2-032:2002; CAT III 600 V, class 2 and pollution deg.2
• This instrument is EN61010-1 certified for Installation Category III (600V). It is recom-
mended for use in distribution level and fixed installations, as well as lesser installa-
tions, and not for primary supply lines, overhead lines and cable systems.
• Do not exceed the maximum overload limits per function (see specifications) nor the
limits marked on the instrument itself. Never apply more than 600 Vdc/600 V ac rms
between the test lead and earth ground.
WARNING
• Before and after hazardous voltage measurements, test the voltage function on a
known source such as line voltage to determine proper meter functioning.
• Disconnect the test leads from the test points before changing meter functions.
• Inspect the Clampmeter, test leads and accessories before every use. Do not use any
damaged part.
• Never ground yourself when taking measurements. Do not touch exposed circuit ele-
ments or test probe tips.
• Do not operate the instrument in an explosive atmosphere.
• To reduce the risk of fire or electric shock, do not expose this product to rain or moi-
sture.
• The meter is intended only for indoor use. To avoid electrical shock hazard, observe
the proper safety precautions when working with voltages above 60 VDC or 30 VAC
rms. These voltage levels pose a potential shock hazard to the user.
• Before and after hazardous voltage measurements, test the voltage function on a
known source such as line voltage to determine proper meter functioning.
• Keep your hands/fingers behind the hand/finger barriers (of the meter and the test
leads) that indicate the limits of safe access of the hand-held part during measure-
ment.
• Inspect test leads, connectors, and probes for damaged insulation or exposed metal
before using the instrument. If any defects are found, replace them immediately.
• This Clamp-on meter is designed to apply around or remove from uninsulated
hazardous live conductors. Individual protective equipment must be used if
hazardous live parts of the installation could be accessible.
• Exercise extreme caution when: measuring voltage >20 V // current >10 mA // AC
power line with inductive loads // AC power line during electrical storms // current,
Содержание ACD-14 PLUS
Страница 2: ......
Страница 3: ...ACD 14 PLUS ACD 14 TRMS PLUS Clamp on Multimeter With Dual Display Users Manual ...
Страница 25: ...22 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Measuring Temperature Figure 8 ...
Страница 27: ...ACD 14 PLUS ACD 14 TRMS PLUS Pince multimètre à double affichage Français ...
Страница 49: ...22 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Mesure de température Figure 8 ...
Страница 51: ...ACD 14 PLUS ACD 14 TRMS PLUS Zangenmessgerät Multimeter mit Doppelanzeige Deutsch ...
Страница 73: ...22 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Messen von Temperatur Abbildung 8 ...
Страница 75: ...ACD 14 PLUS ACD 14 TRMS PLUS Multimetro a pinza con schermo diviso Italiano ...
Страница 97: ...22 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Misure di temperatura Figura 8 ...
Страница 99: ...Italiano ACD 14 PLUS ACD 14 TRMS PLUS Multímetro de pinzas con pantalla doble Español ...
Страница 117: ...18 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Negro Rojo Medición de resistencia Figura 4 ...
Страница 119: ...20 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Negro Rojo SELECT Prueba de diodos Figura 6 ...
Страница 121: ...22 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Medición de temperatura Figura 8 ...
Страница 123: ...Italiano ACD 14 PLUS ACD 14 TRMS PLUS Kläm multimeter med dubbel display Svenska ...
Страница 138: ...15 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Svart Röd SELECT Mäta likspänning Figur 1 ...
Страница 139: ...16 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III SELECT Svart Röd Mäta växelspänning Figur 2 ...
Страница 141: ...18 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Svart Röd Mäta motstånd Figur 4 ...
Страница 142: ...19 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Svart Röd SELECT Kontinuitetstest Figur 5 ...
Страница 143: ...20 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Svart Röd SELECT Testa dioder Figur 6 ...
Страница 144: ...21 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Svart Röd SELECT Mäta kapacitans Figur 7 ...
Страница 145: ...22 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III Mäta temperatur Figur 8 ...
Страница 146: ...23 MAX 600A MAX HOLD ON OFF SELECT MAX COM A Hz ACD 14 PLUS A 600V CAT III X Svart Röd Mäta µA ström Figur 9 ...
Страница 147: ......
Страница 148: ......