9)  Check/Set the Power

   Supply Input Voltage

•  

If the ATX power supply uses auto-ranging operation at 50/60Hz, skip

this step.

•  

Check the input voltage switch on the power supply located on the rear

of the ATX power supply just below the power connector.

The input voltage switch typically has two positions: 115 or 230 volts
– 115 volts is default position.

10)  Verify the Jumper
        Settings

•  

Check the jumper settings just in case a jumper has shifted during

shipping.

•  

Refer to Figures 1-4 and 1-5 for the jumper locations and the Table 1-1,

located at the end of this chapter for the default jumper settings.

11)  Power up the
        MightyBoard 800

  

Plug the CRT monitor’s power cord into an AC outlet and turn on the

monitor.

  

Plug the ATX power supply’s power cord into the AC outlet.

• 

 

Turn the ATX power supply’s power switch to On before continuing.

•  

Press the Green push-button switch on the Utility cable to power up

the MightyBoard 800.

12)  Verify the

 MightyBoard 800
 powers-up satisfactorily

• 

 

Verify the MightyBoard 800 passes POST successfully.

•  

If a bootable device, or the desired operating system is not loaded on

one of the boot devices (floppy drive or CD-ROM) prior to power up,
you will see an error message “Disk boot failure, insert system disk
and press enter” near the end of the boot process.  The boot process
stops until you intervene, by selecting from:

 

Enter BIOS Setup using S for Setup or skip to Step 13.

 

Press R to Reboot the system

 

Turn off the power switch on the ATX power supply.

 

Connect a bootable device to the MightyBoard 800, reapply
power to the system, and then skip to Step 13.

NOTE

Ampro does not recommend using a hard disk drive or CF card
with a preinstalled OS from another model computer to boot
the MightyBoard 800.  This has proven to cause problems or
provide unreliable operation.  Use a bootable device (floppy or
CD-ROM) to load the desired OS onto the hard drive (or CF)
and then the drivers, while still attached to the MightyBoard
800.  Refer to Step 15.

NOTE

For the most current BIOS Information, refer to the Hardware
Release Notes provided as hard copy in the shipping container.

13)  Enter BIOS Setup

  

Press the <Del> key during POST, or S to enter BIOS Setup.

  

Use BIOS Setup during the initial boot to set the desired options

(time and date, alter the boot order of the floppy drive, CD-ROM,
hard disk drive, or select USB boot, LAN Boot, etc.).

•  

Refer to the MightyBoard 800 Reference Manual for all of the

BIOS Setup options, including USB/LAN Boot options.

• 

 

Refer to the next step to alter the boot sequence, while in Setup.

Содержание MightyBoard 800

Страница 1: ...MightyBoard 800 Single Board Computer QuickStart Guide P N 5001775A Revision A...

Страница 2: ...ight to revise this publication from time to time without obligation to notify any person of such revisions If errors are found please contact Ampro at the address listed below on the Notice page of t...

Страница 3: ...ds in identifying the connector locations and components on the board You may find slight variations between your board and the boards shown in this manual to due board revisions Refer to Figure 1 4 a...

Страница 4: ...Contents iv QuickStart Guide MightyBoard 800...

Страница 5: ...fer to MightyBoard 800 Reference Manual Supplied software use and programming Refer to MightyBoard 800 Reference Manual Requirements The following peripherals and devices are needed to make full use o...

Страница 6: ...nce information for your MightyBoard 800 and is located on the MightyBoard 800 Documentation Software Doc SW CD ROM as a PDF file Setting Up the Workspace CAUTION To prevent damage to the electronic c...

Страница 7: ...he Floppy cable to J4 on the edge of the MightyBoard 800 as shown in Figure 1 2 Refer also to Figures 1 1 and 1 4 The Floppy interface uses the standard 34 pin floppy drive connector 2 Connect Primary...

Страница 8: ...to Floppy Connector J4 Standard 34 pin Floppy Cable Figure 1 2 Connecting the Floppy and IDE Cables MB800QkS_03c The Parallel CRT and Serial 1 connectors shown removed for clarity Serial 2 COM2 J6 Con...

Страница 9: ...JP4 B1 U22 U19 U15 JP2 U26 U28 BT1 X3 U17 Q16 Q18 U25 U23 U24 U21 U20 U18 Q21 U27 Y1 X2 X1 U8 U9 Q12 Q13 U14 U7 F1 F2 L3 Q3 Q2 Q4 Q5 Q1 Q7 U1 J7 U10 Y2 U5 U3 U2 Q6 D3 L8 Q14 1 2 3 4 2 1 1 1 1 2 2 2 2...

Страница 10: ...r Connect a USB CD ROM to one of the USB ports Or See USB Boot Support Note at the end of this chapter Ethernet Connection e Connect an Ethernet cable to LAN 1 J15A for the PXE server if you are using...

Страница 11: ...floppy drive or CD ROM prior to power up you will see an error message Disk boot failure insert system disk and press enter near the end of the boot process The boot process stops until you intervene...

Страница 12: ...ve G none Boot Order Boot 1st Drive A Boot 2nd Drive C Boot 3rd none none MB800BtSeqa c Use the Arrow keys and PU PD keys to change the CD ROM into the First Boot Device in the boot order Use the PU P...

Страница 13: ...erence Manual and the Release Notes for additional instructions and information when customizing the BIOS to a particular flat panel NOTE USB Boot Support If you wish to boot from a USB device you mus...

Страница 14: ...l 4 COM4 RS485 Termination Termination pins 3 4 No Termination removed Default U4 U13 J1 J5 J9 J12 J15 J17 U16 J3 DIMM1 J13 J14 J4 J18 J20 J19 J11 J10 JP1 J2 J6 J8 JP4 B1 U22 U19 U15 JP2 U26 U28 BT1 X...

Страница 15: ...ssis clip lead and a wrist or ankle strap Installation Guidelines When handling a DDR DIMM observe anti static discharge precautions to avoid damage The MightyBoard 800 uses up to PC2700 DDR 333 166MH...

Страница 16: ...h a grounded unpainted metal surface to discharge any static electricity 4 Locate the DDR DIMM slot DIMM1 on the MightyBoard 800 See Figure 2 1 DDR DIMM DDR DIMM Slot Retaining Latches 2 MB800QkS_05a...

Страница 17: ...MM ensure the power switch on the power supply is turned off and the power cord has been removed from the power source The typical AT power supply will continue to provide standby current to the board...

Страница 18: ...mum performance The MightyBoard will operate acceptably with a PC2100 DDR 266 133MHz DDR DIMM 6 Ensure there is nothing in the DDR DIMM slot that would prevent its installation 7 Ensure the two retain...

Страница 19: ...not close completely on the DIMM remove it and repeat Steps 7 to 10 12 Reconnect any cables you disconnected earlier and verify all other connections to the MightyBoard 800 are still connected 13 Rec...

Страница 20: ...00 QuickStart Guide MightyBoard 800 Reference Manual Release Notes software drivers and various utilities NOTE You must have an Internet browser to view the main menu and make selections examples Micr...

Страница 21: ...ith a request for the driver s Refer also to the Appendix A Technical Support for more information 5 Install any utilities or other development tools you may need from the MightyBoard 800 Doc SW CD RO...

Страница 22: ...Chapter 2 Installing MightyBoard 800 Options 18 QuickStart Guide MightyBoard 800...

Страница 23: ...sonal assistance by going to the Ask a Question area in the Virtual Technician Requests can be submitted 24 hours a day 7 days a week You will receive immediate confirmation that your request has been...

Страница 24: ...Appendix A Technical Support 20 QuickStart Guide MightyBoard 800...

Страница 25: ......

Страница 26: ......

Отзывы: