Amplicon Liveline PC27E Скачать руководство пользователя страница 9

PC27E

Page 9

4.  USER SETTINGS

4.1

Board Base Address

The PC27E can have its base address situated within the range Hex000 to HexFF0. This
feature provides the flexibility to avoid any contention in I/O mapping that may arise with some
clones and allows the use of multiple cards fitted in the PC expansion slots.

4.1.1

Factory Setting

The board’s base address is set at the factory to be Hex300.

4.1.2

Customer Configured Base Address

The board’s base address can be selected as any sixteenth address within the range Hex000
to HexFF0 by means of the appropriate settings of switch SW1. This switch bank comprises
a row of eight single pole single throw switches with each ‘up’ or ‘ON’ position selecting a
logic 0, and each ‘down’ or ‘OFF’ position selecting a logic 1. The most significant hex digit is
coded by the four most left switches and the middle hex digit is coded by the four most right
switches of SW1.

Figure 1 below shows SW1 with the factory setting of Hex300.

Most significant digit

0011  = Hex3

Middle digit

0000  = Hex0

Least significant  Default

         = Hex0

    

 

   

       

 !""#$%"

FIG. 1 SW1 D.I.L SWITCH SELECTION FOR BASE ADDRESS

4.2

Input/Output Address Space used by the PC27E

The  I/O Addresses of all the port registers used by the PC27E are shown in Table 1, where
BA is the base address of the board (factory configured to HEX300).

Содержание PC27E

Страница 1: ...nformation contained has been reviewed and is believed to be accurate and reliable however Amplicon Liveline Limited accepts no responsibility for any problems caused by errors or omissions Specificat...

Страница 2: ...declare that the product s described in this Instruction Manual are manufactured by Amplicon Liveline Limited and perform in conformity with the following standards or standardisation documents EMC D...

Страница 3: ...Clock Selection 10 4 4 1 Timing for A D Conversions 10 4 4 2 Frequency Measurement 10 4 5 Wait State Generator Setting 11 4 6 Input Voltage Range Setting 11 4 6 1 Input Attenuators 12 5 ELECTRICAL CO...

Страница 4: ...Connector Pin Assignments 15 5 Analog to Digital Converter Output Code 19 6 PC27E Block Diagram 22 7 PC27E Printed Circuit Board Layout 23 8 PC27E Circuit Diagram 24 LIST OF TABLES TABLE TITLE PAGE 1...

Страница 5: ...of the computer system clock frequency The counter timers can also be jumper configured to provide a frequency counter or events counter Conversion can be initiated in 3 different ways the counter ti...

Страница 6: ...into the I O channel expansion slots The PC27E may be installed in any available slot in the machine provided that there is no restriction placed on that slot by the manufacturer of the machine 2 2 R...

Страница 7: ...PC27E software setup program will now run Follow the instructions given on the screen to complete the installation See Section 6 PROGRAMMING for details on running the software 2 5 DASH 27 Optional So...

Страница 8: ...1 2 LSB input ranges Bipolar 2 0 Volts 4 0 Volts Unipolar 0 to 4 0 Volts Input Impedance 100M per channel Multiplexer plus input amp settling time 10 S Cross talk between any 2 channels better than 50...

Страница 9: ...ropriate settings of switch SW1 This switch bank comprises a row of eight single pole single throw switches with each up or ON position selecting a logic 0 and each down or OFF position selecting a lo...

Страница 10: ...an be connected to the TIM input of the PAL A falling edge of TIM will trigger an A D conversion Jumpers J2 J3 and J4 may be positioned according to the required frequency of TIM The connections to th...

Страница 11: ...higher than the 8MHz specified in the ISA standard This option is not fitted as standard Many interface ICs currently available cannot operate at these higher frequencies and it becomes necessary to s...

Страница 12: ...te input voltages to be handled This is accomplished by drilling out a link from the required channel and inserting appropriate resistors Each channel is provided with a position for an input series r...

Страница 13: ...e other 15 channels 1 Insert a single in line resistor network in position RN4 100k would be a suitable value If only one channel is to be equipped with an attenuator then a single 100k resistor can b...

Страница 14: ...ntegrator uses good quality screened cables for external connections It is up to the final system integrator to ensure that compliance with the Directive is maintained Amplicon Liveline offers a serie...

Страница 15: ...12 Volts B7 A7 SD2 0WS B8 A8 SD1 C 12 Volts B9 A9 SD0 O Ground B10 A10 I O CHRDY M S SMEMW B11 A11 AEN P O SMEMR B12 A12 SA19 O L IOW B13 A13 SA18 N D IOR B14 A14 SA17 E E DACK3 B15 A15 SA16 N R DRQ3...

Страница 16: ...Visual Basic analog input demo program TC53DEMO Visual Basic timer counter demo program README User Guide for the Amplicon Introductory DLLs AMPLICON LIVELINE LTD What Amplicon offers you To open any...

Страница 17: ...4 Mode 3 Square Rate Generator 5 Mode 4 Software Triggered Strobe 6 Mode 5 Hardware Triggered Strobe Details of the operation of these various modes are contained in Appendix 82C53 The function of a p...

Страница 18: ...ter by OUT H0307 H46 The two bytes then have to be read from the latch using the command n INP H0305 to read the low order byte followed by n INP H0305 to read the high order byte The two bytes MUST b...

Страница 19: ...rting the conversion and reading the first byte typically 10 s 1 4 7 4 4 3 0 A 0 0 4 7 4 4 3 40 0 A 0 0 1 FIG 5 ANALOG TO DIGITAL CONVERTER OUTPUT CODE 6 6 Programming Hints 6 6 1 Settling Time of Inp...

Страница 20: ...of a few millivolts on this range If necessary the offset could be compensated in software by subtracting the offset value from each sample data 6 6 4 Multiplexer Inputs Please note that all unused an...

Страница 21: ...J7 are positioned according to the table on the screen 6 Connect a precision voltage source between SK1 Pin 4 positive and Pin 22 negative and ground the unused channels by connecting SK1 Pin 5 to Pin...

Страница 22: ...RV1 until the data reading on the screen is 2046 2047 8 Set the voltage source to 3 988 and check the data reading on the screen is 2048 2049 N B No offset adjustment in Bipolar 4v see 6 5 3 B 4 7 C 4...

Страница 23: ...PC27E Page 23 FIG 7 PC27E PRINTED CIRCUIT BOARD LAYOUT...

Страница 24: ...Page 24 PC27E FIG 8 PC27E CIRCUIT DIAGRAM...