5.4.7 Programming via Temposonics service tools
Temposonics sensors can be easily adapted – without opening the
sensor housing – to adjust the measurement operation and parameter
settings. Several service tools are available to easily program the sen-
sor electronically using the sensor's connector or cable. These service
tools are available as separate accessories.
5.4.8 Programming via hand programmer
Hand programmer for Analog output (part no. 253 124), directly con-
nected to the sensor is provided for setup of measuring range by mov-
ing the magnet on desired Null/Span positions (minimum distance
between setpoints: 25 mm) and pushing the corresponding 0 % re-
spectively 100 % buttons on programmer.
NOTICE
In normal function the green LED on sensor is glowing permanently.
Pin 1, GY
When acitvated power supply,
the green LED lights up permanently.
Pin 3, YE
Pin 5, BN
Pin 6, WH
24 VDC
0 VDC
0 %
100 %
Start
24 VDC
0 V / GN
Pin 5, BN (+24 VDC)
Pin 1, GY (Output 1 + programming input)
Pin 3, YE (Output 2 + programming input)
Pin 6, WH (0 VDC)
Start
0 %
100 %
1
2
3
4
5
6
Fig. 78: 1-magnet measurement
1 Magnet position
Active measuring range
1 Magnet sensor
Output 1: position
0 %
100 %
2 Magnets
min. 76 mm
0 %
100 %
2 Magnet sensor
Output1: Position magnet 1, Output 2: Position magnet 2
Fig. 79: Connecting the hand programmer
1. Connect the programmer (Fig. 78) and turn on the supply voltage.
2. Activate the programming mode:
a.) Press the Start button and 100% button simultaneously.
Release the Start button first, wait until the sensor's LED
changes from green to flashing blue, then release the 100%
button.
b.) The flashing blue LED indicates that the sensor is now in
command mode.
3. Adjust the position for the start of output,
(0 % = 0 VDC, −10 VDC, 4 mA, or 0 mA).
a.) Move the magnet to the start position.
b.) Press and hold the 0% button until the flashing blue LED
changes to flashing green, and then release the 0% button.
The LED will then return to flashing blue.
4. Adjust the position for the end of output
(100 % = 10 VDC or 20 mA).
a.) Move the magnet to the end position.
b.) Press and hold the 100% button until the flashing blue
LED changes to flashing green, and then release the 100 %
button. The LED will then return to flashing blue.
5. Save your settings and exit the command mode:
a.) Press and release the Start button. The LED will change from
flashing blue to green on.