Z2
Z6
Z1
-VE (Pin8)
Note :
Triggering any zone via the remote port shall override the previously selected zones. No Priority connection is required.
No connection required for Pin 14 to zone
selector
PIN 8-COM
PIN 7-24V
PIN 6-Z6
PIN 5-Z5
PIN 4-Z4
PIN 3-Z3
PIN 2-Z2
PIN 1-Z1
+
DC 24V
CON
RLY
TRIG
RLY
PR
ZS
PIN 8-COM
PIN 7-24V
PIN 6-Z6
PIN 5-Z5
PIN 4-Z4
PIN 3-Z3
PIN 2-Z2
PIN 1-Z1
+
DC 24V
CON
RLY
TRIG
RLY
PR
ZS
Single Unit Installation With Remote Select
PAGE 4
ZS5601 / ZS5121 | ZONE SELECTOR
SPEAKER Z3
SPEAKER Z2
SPEAKER Z1
FROM POWER
AMPLIFIER 1
POWER AMP 1 POWER AMP 2
24 DC
REMOTE ZONE SWITCHES
The sample connections shown are using a single unit
of either ZS5121 or ZS5601 in a small scale installa-
tion. ie. small number of zone outputs.
Assumptions made are that :
Volume control overriding facilities are done
separately. ( refer example on page 6)
Paging or background music is transmitted only
to the zone selected. (Not uninterrupted
paging system )
Power amplifier unit 1 is to serve zone 1 and 2
Power amplifier unit 2 is to serve zone 3
1.
2.
3.
4.
The diagram above shows installation of a 3 zone system with remote triggering employing external switches. ( this is
optional ). In this case, zone triggering can be made from remote area but the front panel switches has to be at OFF
position.
POWER AMP 1 POWER AMP 2
24 DC
SPEAKER Z3
SPEAKER Z2
SPEAKER Z1
FROM POWER
AMPLIFIER 1
AMPERES PM1060 PAGING
MICROPHONE
8 Core Cable or Single Cat5e
REAR VIEW OF PM1120
AUDIO OUT
(TWISTED PAIR SCREEN)
PIN 1~12: ZONE 1~12
PIN 13 : GND, -VE
PIN 14 : PRIORITY
PIN 15 : +24V DC
The illustration below shows a zone selector
connected to the Amperes PM1060 desktop
paging microphone. This shall provide a better
zone selection than the above configuration.
Two way zone selection can be done, either from
the PM1060 or via the front panel switches of the
zone selector , with PM1060 has a priority
over the former.
Example :
With front panel switches 1 and 2 active, and the
user wishes to page zone 3 only , activation
of zone 3 from PM1060 shall override zone 1 and
2.
Upon releasing zone 3 from PM1060, zone 1 and
2 shall then return to its previous state.