Technical Data
Operating voltage
Consumption
Max load / channels
Cascade limitation
Input circuit
Number of zone
Amplifier input
Zone selection
Indicators
Switch mode
AUDIO
Input impedance (Ohm)
Output impedance
Freq response
Audio input
Max audio output
DATA
Data protocol
Baud rate
Dimension (WxHx D)
Weight
24V DC
6W (250 mA)
500W at 100V line
31 Unit (248 zone)
2
8
8
Front panel switch & remote
Individual zone switch
Individual, All Call Local
zone selection bypassed when remote trigger is actived
Line : 10 K
600 Ohm balanced
70 ~ 15 KHz
Line
Line 1.2V
RS485
19.2 K bps
482 x 44 x 180 mm
2 kg
TD6080 | 8 CH DECODER / ZONE SELECTOR
PAGE 11
Note:
The above specifications are correct at time of printing but subjected to changes without prior notice due to product
improvements.