Technical Specifications
PAGE 11
LS4808 / LS4816 | 8 / 16 CHANNEL SPEAKER LINE SURVEILLANCE
Summary Of Features
■
■
■
■
■
■
■
■
■
■
■
■
Note:
The above specifications are correct at time of printing but subjected to changes without prior notice due to product
improvements.
8 / 16 channel speaker line monitoring and expandable
Basic and Advance level of detection setup
Detection of faulty cable and speaker in individual zone or circuit
Impedance measurement method - no capacitor coupling required and cable branching allowed.
Faulty circuit disconnection option
Built in impedance meter, range within 10 Ohm to 10 K Ohm
LCD display to facilitate system setup, measurement and monitoring
Fault alert with LED indicators and switchable buzzer
Detection test interval setting from 1 min to 48 hours
Short burst test signal, minimizing interruption to PA operation
User setting for detection sensitivity for open, short and leakage
Aux 24V DC output for volume controller overriding during testing mode
LS4808
LS4816
24V DC via PS9400 adaptor
3.8W
10 to 1000W 100V line
1 KHz
5V sine
0.5 second per channel (max)
User preset from 1 min to 48 hrs
Continuous buzzer with Off option
3A
482 x 44 x 180 mm
2.20kg
4.9W
5% within range
User preset at each channel
3.25kg
STM 32 microprocesser
8
10 to 10 K Ohm
Normal, Fault, Buzzer, Auto run
Operating voltage
Power consumption
Capacity (channel)
Processor
Impedance detection range
Power measurement range
Measurement accuracy
Pilot tone injection frequency
Pilot tone signal output level
Monitor triggering
Transmittal detection period
Detection interval
Sensitivity setting
Indicators - LED
Display LCD
Audible output signal
Dry contact setting
DC output in detection mode
Dimensions (W x H x D)
Weight
2 x 16 characters w back light
24V DC
16
482 x 88 x 180 mm
Auto / remote trigger