background image

AX3700

6 Duty / 1 Standby Auto Amplifier Changeover Panel

Features

technical specifications

application schematic

auto amplifier changeover

Amperes AX3700 offers a great flexibility and simplicity in cabling for auto amplifier fault changeover system with its combination of amplifier 

fault sensor modules and changeover panel in a box. The internally generated Pilot Tone and sensory circuit shall detect any faulty duty 

amplifier and would initiate a changeover process.

AX3700 has been optimised for faster fault detection and changeover as compared with AS4000 modules. Pilot tones are generated at 

intervals to avoid constant loading of power amplifiers.

Changeover are performed at both input and output sections, making it suitable for application in a matrix system. At any one time, only a 

failed duty unit shall be replaced by a standby amp, to avoid overloading.

Cater for 6 duty and 1 standby 
Expandable for 1 standby to cater for more than 6 duty amps.
Built in Pilot Tone generator, transmit at intervals and senses at 
sequence to protect amplifiers
Overloading protection by allowing only a single take over
Prioritised changeover which higher numbered amplifier shall be 
preferred for take over if more than two units are down
Shorter fault detection time from 10 to 25 seconds
Changeover at input and output section simultaneously ; suitable 
for matrix system installations
Input link switch ; making connection of sources easier
Channel isolation switch for unused or un-monitored channel
Individual channel status indicators ; normal, fault and changeover

Operating voltage
Power consumption
Input signal
Input impedance
Audio output gain
Pilot tone interval
Pilot tone frequency
Detection line
Detection level
Failure detection time
Failure recovery time
Zone load rating
Status indications
Changeover alert
Changeover section
Dimensions (WxHxD)
Weight

24V DC 1 A via PS9400 PSU
7.2 W
6 ch. balanced line signal
10 K Ohm
Unity
10 secs / channel
20 KHz ( +/- 5% )
70 / 100 V line
50 V rms
10 ~ 25 seconds
20 seconds max
400W / 100V line
Normal ; Fault ; Changeover
Buzzer with switch
Input and Output simultaneously
482 x 88 x 150 mm
3.4 kg

5121
ZS

OVERRIDE

2

1

3

5

4

SPEAKER ZONE SELECT

6

7

8

9

10

12

11

CALL

ALL

amperes

O

I

PA 2120

amperes

SIGNAL -40 dB

SIGNAL -10 dB

POWER
PROTECT
CLIP

2120

PA

120 Watts

POWER

O

I

PA 2120

amperes

SIGNAL -40 dB

SIGNAL -10 dB

POWER
PROTECT
CLIP

2120

PA

120 Watts

POWER

O

I

PA 2120

amperes

SIGNAL -40 dB

SIGNAL -10 dB

POWER
PROTECT
CLIP

2120

PA

120 Watts

POWER

amperes

AX 3700

5

6

4

3

2

1

BUZZER

AMP/LINE 

ALERT

FAULT

CHANGEOVER

AMP. NUMBER

FAULT

NORMAL

S/BY

POWER

ON / OFF

PILOT TONE ACTIVE

TEST

MIC

SIREN ACTIVATE

POWER

FIRE

amperes

AM 6000

O

I

2122

MX

amperes

SIG IN

AUX

MAX

MIN

MAX

MIN

MAX

MIN

MAX

SIG IN

SIG IN

CH2

CH1

CH3

MIN

MIN

MAX

MIN

MAX

SIG IN

SIG IN

SIG IN

CH4

CH6

CH5

TONE CTRL

MIN

MAX

TREBLE

MIXER

CHIME

SIG IN

MIN

SOURCE

MIN

MAX

MAX

EXT INPUT

MIN

MAX

BASS

SIG IN

MUSIC SOURCE

MASTER

OFF

CASS

CD

TUNER

SELECT

OFF

POWER

INPUT SOURCES

E/M

PANEL

DUTY AMP

DUTY AMP

STANDBY

AMP

ZONE

SELECTOR

SPEAKERS

VOL

CTRL

AX3700

24V DC

overriding

100V

100V

audio +

PT

100V

audio

24V DC

overriding

1

6

s/by

1

6

100V

Cascade AX3700 is more than 6 duty 

amps are installed

rear view

IN-

IN+

OUT+

IN-

IN+

OUT+

OUT-

OUT-

IN+

IN-

CHANNEL 1

CHANNEL 2

CHANNEL 3

CHANNEL 4

CHANNEL 5

CHANNEL 6

STANDBY

AMP 

CHAN. 1

ON

CHAN. 2

ON

CHAN. 3

ON

CHAN. 4

ON

CHAN. 5

ON

CHAN. 6

ON

HIGH

CASCADE

LOW

CHANNEL 6

DC 24V

0.5 A

+

-

IN-

IN+

OUT+

IN-

IN+

OUT+

OUT-

OUT-

IN-

IN+

OUT+

IN -

IN +

OUT +

OUT -

OUT-

+

- G + -

INPUT

OUTPUT

CHANNEL 5

+

- G + -

OUTPUT

INPUT

CHANNEL 4

+

- G + -

OUTPUT

INPUT

CHANNEL 3

+

- G + -

OUTPUT

INPUT

CHANNEL 2

+

- G + -

OUTPUT

INPUT

CHANNEL 1

STANDBY

+

- G + -

+

- G

OUTPUT

INPUT

OUTPUT

OPEN

LINK

LINK

SIGNAL

OPEN

LINK

LINK

SIGNAL

OPEN

LINK

LINK

SIGNAL

OPEN

LINK

LINK

SIGNAL

OPEN

LINK

LINK

SIGNAL

AX3700

PLEASE OBSERVE POLARITY

OUT +/- --> TO ZONE SELECTOR / SPEAKERS

AMP CONNECTIONS

IN +/- --> FR. AMP OUTPUTS

MAX LOAD / CH - 400W / 100V LINE

AMP. AUTO 

FAULT

CHANGE OVER

AMPLIFIER 70/100V LINE INPUTS/OUTPUTS

CHANNEL / AMP. DETECTION SWITCHES

SWITCH TO OFF FOR UNUSED CHANNEL

FAULT

CONT.

3A NO

MAX

AUDIO SIGNAL INPUTS / OUTPUTS

RS 485

INPUT SIGNAL
DO NOT SWITCH TO LINK WHEN DIFFERENT AUDIO

SOURCES ARE USED FOR THE ADJACENT CHANNEL

CASCADE
CONNECT ONLY ONE WIRE FOR CASCADE TO NEXT 

UNIT

UNIT 1(LOW) --- UNIT 2(HIGH)

A B

Carton 

 : 555 (W) x 165 (H) x 295 (D) mm

Weight

 : 4.2 kg

Qty

 : 1 units / carton

packing information

amplifie

r changeover & monitor

ing

www.ampereselectronics.com

Page 18

2009 : all rights reserved by amperes electronics sdn bhd

the emerging preference