background image

AM6000

6 Ch. Amplifier Monitor Panel

Features

technical specifications

application schematic

amplifier monitoring

AM6000 shall be used to monitor the condition of amplifier outputs of 70 / 100V 

line at the rack which is equipped with level meter, amplifier output LED and 

speaker for audio monitoring. It can also be used as a tool to calibrate sound 

output level of each amplifier from the rack.

6 inputs for 70 / 100 V line amplifier outputs
Dual mode monitoring with continuous signal indicator
Audio monitoring with volume control

Operating voltage
Power consumption
Amplifier inputs
Monitoring mode

Dimensions (WxHxD)
Weight

24V DC via PS9400 PSU
50 mW
6 : 70 / 100V line
Audio : 1 W speaker with 5 presets
Visual : 9 segment LED level meter
LED for all channels
482 x 88 x 130 mm
2.3 kg

Carton  

: 555(W) x 165(H) x 295(D) mm

Weight

: 3.1 kg

Qty

: 1 units / carton

packing information

CAUTION : PLEASE OBSERVE POLARITY

AMPLIFIER INPUTS

AMP 4

100V

DC SUPPLY

24V,1A

+

AMP 2

AMP 3

AMP 1

C

O

M

100V

-

100V

C

O

M

C

O

M

100V

AMP 5

AMP 6

C

O

M

C

O

M

100V

100V

C

O

M

AMP 6

AMP IN   -  FROM AMPLIFIER OUTPUT

PLEASE OBSERVE LINE POLARITY

TO ZONE SELECTOR / SPK

AMP 1

AMP IN 6

AMP IN 1

AM 6000

AMPLIFIER MONITOR PANEL WIRING DIAGRAM

A

60

00

rear view

AS4000

Amplifier Surveillance Module

AS4000 is used to monitor the status of 70 / 100 V line power amplifiers 

which  do  not  have  built  in  detection  module.  Every  amplifier  shall 

employ one AS4000 and the dry contact output from the unit shall then 

be connected to Amperes AX700. Repeating this link shall then form an 

automatic amplifier fault changeover / surveillance system.

Interval Pilot Tone injection ; reduces strain to amplifiers
Works independently with or without availability of audio signal
Low distortion to original audio signal
Status monitoring via LED ; Pilot Tone and amplifier fault
Compatible with most 70 / 100 V line amplifiers in the market

Features

Operating voltage
Power consumption
Input impedance
Output impedance
Max audio input
Max audio output
Transmit interval
Detection delay
Recovery time
Frequency response
Detection output
Dimensions (WxHxD)
Weight

24V DC via PS9400 PSU
200 mW nominal
10 K balanced
600 Ohm balanced
0.75 V
1.2 V
10 seconds
20 seconds
30 seconds
20 - 20 KHz
NO and NC dry contact
120 x 96 x 28 mm
330 gms

technical specifications

Please refer to schematic in AX700 ; “ Application 

with AS4000 amplifier surveillance module “

www.ampereselectronics.com

Page 19

2009 : all rights reserved by amperes electronics sdn bhd

the emerging preference

amplifie

r changeover & monitor

ing