AM6000
6 Ch. Amplifier Monitor Panel
Features
technical specifications
application schematic
amplifier monitoring
AM6000 shall be used to monitor the condition of amplifier outputs of 70 / 100V
line at the rack which is equipped with level meter, amplifier output LED and
speaker for audio monitoring. It can also be used as a tool to calibrate sound
output level of each amplifier from the rack.
6 inputs for 70 / 100 V line amplifier outputs
Dual mode monitoring with continuous signal indicator
Audio monitoring with volume control
Operating voltage
Power consumption
Amplifier inputs
Monitoring mode
Dimensions (WxHxD)
Weight
24V DC via PS9400 PSU
50 mW
6 : 70 / 100V line
Audio : 1 W speaker with 5 presets
Visual : 9 segment LED level meter
LED for all channels
482 x 88 x 130 mm
2.3 kg
Carton
: 555(W) x 165(H) x 295(D) mm
Weight
: 3.1 kg
Qty
: 1 units / carton
packing information
CAUTION : PLEASE OBSERVE POLARITY
AMPLIFIER INPUTS
AMP 4
100V
DC SUPPLY
24V,1A
+
AMP 2
AMP 3
AMP 1
C
O
M
100V
-
100V
C
O
M
C
O
M
100V
AMP 5
AMP 6
C
O
M
C
O
M
100V
100V
C
O
M
AMP 6
AMP IN - FROM AMPLIFIER OUTPUT
PLEASE OBSERVE LINE POLARITY
TO ZONE SELECTOR / SPK
AMP 1
AMP IN 6
AMP IN 1
AM 6000
AMPLIFIER MONITOR PANEL WIRING DIAGRAM
A
M
60
00
rear view
AS4000
Amplifier Surveillance Module
AS4000 is used to monitor the status of 70 / 100 V line power amplifiers
which do not have built in detection module. Every amplifier shall
employ one AS4000 and the dry contact output from the unit shall then
be connected to Amperes AX700. Repeating this link shall then form an
automatic amplifier fault changeover / surveillance system.
Interval Pilot Tone injection ; reduces strain to amplifiers
Works independently with or without availability of audio signal
Low distortion to original audio signal
Status monitoring via LED ; Pilot Tone and amplifier fault
Compatible with most 70 / 100 V line amplifiers in the market
Features
Operating voltage
Power consumption
Input impedance
Output impedance
Max audio input
Max audio output
Transmit interval
Detection delay
Recovery time
Frequency response
Detection output
Dimensions (WxHxD)
Weight
24V DC via PS9400 PSU
200 mW nominal
10 K balanced
600 Ohm balanced
0.75 V
1.2 V
10 seconds
20 seconds
30 seconds
20 - 20 KHz
NO and NC dry contact
120 x 96 x 28 mm
330 gms
technical specifications
Please refer to schematic in AX700 ; “ Application
with AS4000 amplifier surveillance module “
www.ampereselectronics.com
Page 19
2009 : all rights reserved by amperes electronics sdn bhd
the emerging preference
amplifie
r changeover & monitor
ing