Troubleshooting
3A1602J
A side rich; lack of B side.
A side gauge is low.
B side restriction downstream of
gauge. Check gun check valve
screen, mix module, or mix manifold
restrictor.
B side gauge is low.
B side material supply problem.
Check B side inlet strainer and
pump intake valve.
B side rich; lack of A side.
A side gauge is low.
A side material supply problem.
Check A side inlet strainer and
pump intake valve.
B side gauge is low.
A side restriction downstream of
gauge. Check gun check valve
screen, mix module, or mix manifold
restrictor.
Problem
Cause
Solution