Type
Description
Function
Example Application
LED4
4 x LED Output
Module
Provides 4 x Output LEDs
that mimic the state of an
input module with the
same address.
Alternatively, LEDs can be
remotely controlled by the
iMAC2 Controller.
Control LED outputs at remote locations
e.g. indicate remote isolation, status of
conveyor signal lines etc.
Can be used in hazardous areas.
LIM
LED Indication
Module
Provides 7 selectable LED
profiles for green, yellow
or red flash sequences.
Responding to a 4-20mA Analogue Input
with green, yellow or red LED indication.
Serial Interface Modules
The iMAC System allows certain external equipment to communicate with the iMAC2 Controller through the
use of Serial Interface Modules. These modules form a communication bridge between the iMAC System
and compatible RS485 Modbus devices, allowing up to 16 Modbus Holding Registers to be read from a
Modbus Slave RTU device and be transmitted to an iMAC2 Controller across the iMAC Fieldbus.
Type
Description
Function
Example Application
SIM-G
Serial Interface
Module
– 1 x
GasGuard Controller
Communications Bridge
between the iMAC System
and a single GasGuard
C
ontroller’s RS485
Modbus interface.
Allows RS485 Communications from a
GasGuard Controller installed in the field to
be transmitted back to the iMAC2
Controller over the fieldbus.
Can be used in hazardous areas.
SIM-G2
Serial Interface
Module
– 2 x
GasGuard
Controllers
Communications Bridge
between the iMAC System
and two GasGuard
Controllers' RS485
Modbus interfaces.
Allows RS485 Communications from two
GasGuard Controllers installed in the field
to be transmitted back to the iMAC2
Controller over the fieldbus.
Can be used in hazardous areas.
SIM-P
Serial Interface
Module -
Programmable
Modbus RTU
Communications Bridge
between the iMAC System
and a compatible RS485
Modbus RTU device
Transfers up to 16 Modbus registers from a
Modbus RTU slave device to the iMAC2
Controller over the fieldbus.
Can be used in hazardous areas.
SIM-T
Serial Interface
Module -Trolex
™
9042 Controller
Communications Bridge
between the iMAC System
and a Trolex
™ 9042
Controller’s RS485
Modbus interface
Allows RS485 Communications from a
Trolex
™ 9042 Controller installed in the
field to be transmitted back to the iMAC2
Controller over the fieldbus.
Can be used in hazardous areas.