Important Safety Instructions: Read Before Installation

INSTALLATION & MAINTENANCE GUIDE

This luminaire is intended for installation in accordance with local codes and 

the National Electric Code (NEC). Failure to adhere to these codes and

instructions may result in serious injury, property damage and void the 

warranty.

These instructions do not intend to cover all variations in installation, 

operation maintenance or mounting situation. 

1.  Make sure that the power is turned OFF before installing or servicing this 

luminaire. 

2.  Warning: risk of electrical shock.  Install all luminaires 10 feet (3.05M) or 

more from pool, spa or fountain.

3.  This luminaire is intended to be used only with a power supply 

(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.

4.  Wiring connections must be made with wire connectors that is suitable 

for outdoor use.

5.  Position the low voltage wire and wire connector so that it is located 

within 6 inches (15.2 cm) from a building structure, a luminaire, or 

fitting.

6.  The main low voltage cable is intended for shallow burial - less than 6 

inches (152 mm).

7.  If additional lengths of low voltage cable is required, please contact 

www.amplighting.com or call 1-813-978-3900.

!

w w w. a m p l i g h t i n g . c o m

–2–

SAVE THESE INSTRUCTIONS

Содержание ADL Series

Страница 1: ...AMP Low Voltage Landscape Lighting AMP Deck Lights Integrated ADL Series INSTALLATION MAINTENANCE GUIDE Help Hotline 1 813 978 3900 Mon Fri 9am 6pm EST www amplighting com...

Страница 2: ...vicing this luminaire 2 Warning risk of electrical shock Install all luminaires 10 feet 3 05M or more from pool spa or fountain 3 This luminaire is intended to be used only with a power supply transfo...

Страница 3: ...and run the lead wire out the backside of the location so that the wires are not visible from the front side Use a matching trim piece and cut a groove in the back of trim Cover the lead wires with th...

Страница 4: ...otection Align the notches on the cover to the base Firmly rotate the cover until it locks Luminaire Cover Cover Base Base Install Base 2 Attach the base on the wall making sure the arrow is pointing...

Страница 5: ...ire Connections 4 Strip both leads from the luminaire pigtail Using two wire connectors sold separately connect the leads from the luminaire to the main low voltage supply cable leads Luminaire Wire C...

Страница 6: ...AMP Deck Lights Integrated ADL Series INSTALLATION MAINTENANCE GUIDE 6 www amplighting com 6...

Страница 7: ...customersupport amplighting com 813 978 3900 7...

Страница 8: ...s and product details subject to change without notice Copyright 2018 AMP Lighting Lutz FL USA 33549 All rights reserved customersupport amplighting com 813 978 3900 Help Hotline 1 813 978 3900 Mon Fr...

Отзывы: