User Guide ATU v.5.0 Test
kit.docx-5.0
8 Register operations (ATU-1 and ATU-2)
Before changing any register value it is highly recommanded to read the AMO
– ABSYS Interface Description – BiSS/C (
https://www.amo-gmbh.com/
)
starting with Revision 07 and also please be carefull to the Encode Interface
Revision (Address 0x7D).
Access to the register is possible with ATU-1 and ATU-2 devices.
The ATU Unit must be connected to USB Port and also initialized in the ATU Software (by
pressing the "Connect Device" button).
The ATU Software allows accessing 128 Bytes (0x00 – 0x7F) from the BiSS-C Encoder registers.
"Get Register" button reads all the registers form the current slave.
By double-clicking on a value, the user is able to type a new value for the register. All
values are in hexadecimal.
After changing one or several values use the button "Save to Register" to transmit data to
BiSS-C Encoder/Slave and save them to the Non-Volatile Memory (Flash).
User can update the register values also by writing new values in the String Data text box. String
Data have higher priority, what means that they override values from table. The new values must
be entered in *.mem file format:
o
First value (hex in 0x?? format) defines the address
o
Next numbers (hex in ?? format) represents the new register values starting with
address from above
Example:
String Data
0x30 0A 09 45 F2 0x70 12
Result