The company Ammonite System will not be held responsible for 
any damage resulting from the misuse of ACCU battery.

CHARGING THE LI-ION BATTERY

To charge the battery, you must connect the charger to a 
100–240 V ~ power source. 
Proper performance of the charger is indicated on the blue 
backlit display. 
The output plug of the charger must be connected to the  
battery charging terminal.
The charge start is indicated by the display changing its colour 
from blue to red and displaying information on the battery pack 
charge status.

The indications on the charger display are only 
approximate. They serve to determine the 
estimated battery level.

USE OF THE LI-ION BATTERY:

The battery must be charged only with the AMMO LITHIUM 
CHARGER supplied by Ammonite System.
The battery must not be discharged below the voltage level of 
8.0 V (15% on the battery charger display).

PERFORMING THE 
FOLLOWING IS PROHIBITED:

 

Open/cut the protective wrap of the battery pack.

 

Interfere with the battery construction.

 

Short-circuit the battery contact pins.

 

Use ACCU battery with other batteries than genuine 

 

Ammonite System battery packs.

 

Throw the battery or pierce the cells’ casing 

 

Put the battery into fire.

 

Immerse the battery pack into the water.

STORAGE CONDITIONS OF LI-ION 
BATTERIES

The battery should be stored in a dry, ventilated room in  
ambient temperatures from +10 °C to +40 °C.
Temperatures higher than +60 °C may cause damage to the 
internal parts of the battery.
Charging the battery must always take place in a positive  
temperature: from 10 °C to +40 °C.
If the battery was stored in negative temperature, it is 

 

necessary to let it adjust by leaving it in a temperature of at least  
+10 °C for 4-5 hours. 
While diving in winter, you must not store the battery in a  
negative temperature (e.g. in a car boot or outdoors).
Charging a frozen battery may result in damage to its internal 
parts.
Discharge of the battery may take place in temperatures  
ranging from +10 °C to +40 °C.
The battery may be stored after prior charge up to 70%-100% 
(storing a discharged battery leads to its deterioration).
The battery must be stored away from sources of fire and 
damp, as well as food.
When stored, the battery must be charged at least once  
every six months or more often if the voltage on its connection  
terminal amounts to less than 8.5 V (20% on the charger 
display).
You must check the voltage/capacity on the battery connection 
terminal once a month using the charger included in the kit or 
another appropriate measuring instrument.