7.5. Digital output
On Pin 2 of the socket for the external power supply there is a switching output.
When inactive this has a high resistance, in the active state it is drawn to
ground.
There are several ways to activate the digital output:
•
Automatically, as long as the modem is switched on
(configuration in GSM-window)
This function is only necessary if you have to switch your own modem by
means of a relay. The switched output is not needed for the Ammonit GSM-
systems, so that remains available for other uses.
•
Automatically, as long as the SMR registers data (configuration in SMR
window)
Using this function a wind alarm system can be created: as soon as a
threshold value is exceeded and the SMR switched on, the switched output
is also activated (and if required an SMS text message will be sent).
•
Manually via "Callalog" or SMS text message command
The manual control is often used to switch on sensor heating, e.g. a relay-
controlled accumulator. Since only a limited amount of power is usually
available in stand-alone systems, this function can now be used to switch
the heating on remotely when it is really needed.
Содержание METEO-32
Страница 1: ...measuring wind power WICOM 32 Data Logger Datenlogger Series 32 METEO 32X METEO 32 www ammonit com...
Страница 35: ...Ammonit Data Logger Manual 34 Ammonit GmbH 2005 2009...
Страница 47: ...Ammonit Data Logger Manual 46 Ammonit GmbH 2005 2009...
Страница 57: ...Ammonit Data Logger Manual 56 Ammonit GmbH 2005 2009...
Страница 72: ...Annex Ammonit GmbH 2005 2009 71 3 plug Wind Plan view Data Logger 4 plug Meteo Plan view Data Logger...
Страница 73: ...Ammonit Data Logger Manual 72 Ammonit GmbH 2005 2009 4 plug Xtend Plan view Data Logger...