Ammonit Data Logger Manual
24
Ammonit GmbH / 2005 - 2009
3.1.3. Pre-evaluation in the log interval
The scan values acquired within a log interval can be separately programmed
and calibrated for each channel.
3.1.4. Storage organisation or time series
The shift register for the measurement series is subdivided into blocks. Each
block encompasses one day; the system automatically inserts a block mark after
midnight. Each block mark has a time code assigned to it. After the entire
memory is allocated, the oldest block - this corresponds to one day - is deleted.
When the system is being programmed such that the entire
memory is occupied before a block mark has been set, the system
stops logging the time series when there is no more space. In this
case it is only possible to free the memory by pressing "Reset".