3.3. Slow Motion Recorder (SMR)
The Ammonit Data Logger can also be used to record wind data in slow motion
over a short period. After being started by a programmable event, the wind input
data will be stored at selected intervals directly into a separate read-only
memory. In all, 180 measurement lines can be recorded; this corresponds for 1-
second measurement intervals to a duration of 3 minutes, for lower
measurement frequencies a correspondingly longer period of time will be
covered. Like the statistical data, the data will only be transferred when called
up.
Various events can trigger the signal which starts measurements:
•
An individual wind speed 1 above the pre-set threshold value
•
A mean value over 3 seconds of the wind speed 1 exceeding the pre-
set measurement value
•
A start signal is given by an online command via the CALLaLOG
software
•
A start signal is sent to the Logger using the text message (SMS)
command "T"
To allow you to make best use of this option, several parameters can be
adjusted:
•
The threshold for the start signal in [dm/s].
•
The switching output is activated during a recording
•
Recurring recordings are possible, in case there is a new event
•
After a measurement, the initial measurement value can be set as the
new threshold
Содержание METEO-32
Страница 1: ...measuring wind power WICOM 32 Data Logger Datenlogger Series 32 METEO 32X METEO 32 www ammonit com...
Страница 35: ...Ammonit Data Logger Manual 34 Ammonit GmbH 2005 2009...
Страница 47: ...Ammonit Data Logger Manual 46 Ammonit GmbH 2005 2009...
Страница 57: ...Ammonit Data Logger Manual 56 Ammonit GmbH 2005 2009...
Страница 72: ...Annex Ammonit GmbH 2005 2009 71 3 plug Wind Plan view Data Logger 4 plug Meteo Plan view Data Logger...
Страница 73: ...Ammonit Data Logger Manual 72 Ammonit GmbH 2005 2009 4 plug Xtend Plan view Data Logger...