119
ASC 70
275104
1
1
MAINTENANCE MANUAL
3.6.11. Battery check
• Stop the engine and disconnect the electric system using
the isolating master switch.
• Clean the surface of batteries.
• Check the condition of poles and terminals (1) and clean
them. Slightly wipe terminals with grease.
MAINTENANCE-FREE BATTERY
• In case of a maintenance-free battery (the battery has no fre-
ely accessible plugs), only the no-load voltage on terminals
is checked. The batteries cannot be replenished. If the no-
-load voltage is 12.6 V and more, the battery is fully charged.
If the no-load voltage is below 12.4 V, the battery should be
charged immediately. After the battery is charged, leave it
to stand for 2–3 hours and then measure the voltage again.
It is recommended to be mounted 24 hours after charging.
Note:
The no-load voltage is the voltage measured at the terminals of
the battery which was at rest for at least 12 hours – was neither
charged nor discharged.
Keep the batteries dry and clean.
Do NOT disconnect battery while the en-
gine runs.
When handling with the battery, always
follow battery Manufacturer’s Manual!
Use rubber gloves and eye protection aids
when handling the battery.
Use proper clothing to protect your skin
against any electrolyte stain.
When there is eye contact with electrolyte
immediately flush affected eye with large
amounts of water for a few minutes. Get
prompt medical attention.
When there is electrolyte ingestion, drink
max amount of milk, water, or solution of
calcined magnesia in water.
During skin contact with electrolyte, re-
move clothing, including shoes, flush af-
fected points as soon as possible with
soap water or solution of soda and water.
Get prompt medical attention.
Do NOT eat, drink or smoke while at work!
After work is completed, wash your hands
and face thoroughly with water and soap!
Do NOT check a wire is energized by
touching Machine frame.
Disconnect the battery before its repair,
or when about to handle the wires and
electric devices within the wiring circuit
so to avoid a short circuit.
When disconnecting the battery, please
disconnect cable with (-) pole first. When
connecting, you must connect (+) pole
first.
Making direct conductive connection be-
tween battery’s both poles you will cause
a short circuit with battery explosion
hazard.
Do NOT turn over the batteries, electrolyte
may pour out from degassing batteries.
When there is electrolyte spillage, rinse
the affected place with water, and neu-
tralize with lime.
Hand over old batteries that do not work
for their disposal.
Содержание ASC 70
Страница 1: ...ASC 70 OPERATING MANUAL SINGLE DRUM ROLLER CUMMINS Tier 3 EDITION 10 2018 EN From Serial No 2742519...
Страница 2: ......
Страница 4: ...iv ASC 70...
Страница 12: ...8 ASC 70...
Страница 13: ...9 ASC 70 SPECIFICATION MANUAL 1 SPECIFICATION MANUAL ASC 70 Cummins Tier 3...
Страница 22: ...18 ASC 70 Notes...
Страница 23: ...19 ASC 70 OPERATION MANUAL 2 OPERATION MANUAL ASC 70 Cummins Tier 3...
Страница 24: ...20 ASC 70...
Страница 97: ...93 ASC 70 OPERATION MANUAL Notes...
Страница 98: ...94 ASC 70 Notes...
Страница 99: ...95 ASC 70 MAINTENANCE MANUAL 3 MAINTENANCE MANUAL ASC 70 Cummins Tier 3...
Страница 100: ...96 ASC 70...
Страница 158: ...154 ASC 70...
Страница 164: ...160 ASC 70 3 8 Annexes...
Страница 179: ...175 ASC 70 MAINTENANCE MANUAL Notes...
Страница 180: ...176 ASC 70 3 8 Annexes Notes...
Страница 181: ...177 ASC 70 MAINTENANCE MANUAL Notes...
Страница 182: ...178 ASC 70 3 8 Annexes Notes...
Страница 183: ......