background image

©Copyright AMKUS Rescue Systems 2020-2021

7

LAP-012 October 7, 2021 Rev02

3.0 GENERAL DESCRIPTION

For two-tool simultaneous operations, the 240SS Super Simo is a true “on board” 2 circuit hydraulic rescue tool power unit. This high

performance unit provides the power and tool speed needed to be used with longer length hoses such as 100, 150, and even 200 foot

length hoses. The performance of the 240SS virtually eliminates long tool reaction times created by the expansion of long lengths of

hydraulic hoses.
AMKUS uses another industry first, Variable Frequency Drives to regulate electrical requirements. This infinitely customizable control

system is set up to require only 5 amps of current at start up. Unlike other electric power units, the 240SS increases electrical power as

the pressure increases through the use of a Programmable Logic Controller (PLC). Maximum electrical requirement of less than 15kW is

needed only when both circuits reach 10,500 psi simultaneously.
The Programmable Logic Control Module puts the controls in one location providing master on/off switch, circuit controls, low oil, high

temperature indicator lights. The Human Machine Interface (HMI) display provides system operational information as well as input and

output indicators to quickly troubleshoot the system. An Ethernet interface provides a programming and troubleshooting connection for

factory assistance should the need occur to interface to the power unit.

4.0 SPECIFICATIONS

Table 4.0

Length

33 in

838 mm

Width

10.25 in

260 mm

Height

21 in

533 mm

Weight

217 lbs (wet)

98.4 kg (wet)

177 lbs (dry)

80.3 kg (dry)

Motor Input Voltage

208/240  VAC Single Phase

Current Draw Amps (maximum)

70 Amps @ 208VAC (input)

Number of Pumps

2

Rated Flow of Pump Per Port (Stage 1)

1 gpm

3.9 L/min

Rated Output Pressure (Stage 1)

6450 psi

445 bar

Rated Flow of Pump Per Port (Stage 2)

0.68 gpm

2.6 L/min

Rated Output Pressure (Stage 2)

10,500 psi

724 bar

Fluid Type

AMKUS MV1 Mineral Base Hydraulic FluidSafety Data Sheet 

(SDS) for AMKUS MV1 Hydraulic Fluid is available at 

AMKUS.com and CHEMTREC.com

(For equipment stored and operated in environments below 32 

deg. F (0 deg C) contact Amkus Rescue Systems for 

recommendation.

Hydraulic Fluid Reservoir Capacity

7 gal (US)

26.5 L

Hydraulic Filter Replacement

AMKUS Part # KSS010

Содержание Super Simo 240SS

Страница 1: ...al protective equipment is a misuse of AMKUS equipment Obtain safety information at amkus com This instruction manual is intended to familiarize operators and maintenance personnel with the operation basic maintenance and safety procedures associated with this product This manual should be kept available to all operating and maintenance personnel This manual does NOT address servicing of AMKUS Res...

Страница 2: ...SPONSIBILITY to know that you have been properly trained in Firefighting and or Emergency Response and in the use precautions and care of any equipment you may be called upon to use 4 IT IS YOUR RESPONSIBILITY to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use 5 IT IS YOUR RESPONSIBILITY to know that your equip...

Страница 3: ... n I l l i p S Health Information Recommend use of the chemical and restrictions on use l i o c i l u a r d y H e s U d e d n e m m o c e R SECTION 2 HAZARDS IDENTIFICATION 6 ODVVL cation Not a hazardous substance or mixture GHS Label element d e r i u q e r l o b m y s d r a z a h o N s m a r g o t c i p d r a z a H d r o w l a n g i s o N d r o w l a n g i S S D R A Z A H L A C I S Y H P s t n e...

Страница 4: ...ING THE UNIT 7 2 3 FILLING THE UNIT 7 2 4 CONNECTING THE PRESSURE AND RETURN HOSES 7 2 5 HEAT EXCHANGER 7 2 6 CONTROL PANEL 7 2 7 VFD PANEL 7 2 8 WIRELESS REMOTE CONTROLS OPTIONAL 8 0 INITIAL START UP 9 0 OPERATION 9 1 GENERAL 9 2 OPTIONAL WIRELESS REMOTE CONTROL 9 2 1 FEATURES 9 2 2 OPERATING INSTRUCTIONS 10 0 TROUBLESHOOTING GUIDE 11 0 ROUTINE MAINTENANCE 11 1 HYDRAULIC PUMP 11 1 1 OIL CHANGE PR...

Страница 5: ...ep covers and guards in place and in working order WARNING Using rescue tools can cause ignition or explosion resulting in injury or death Ignition or explosion can result from situations such as Flammable hazards are created when fuel lines refrigerant lines atomized oil or pressurized hydraulic fluid lines are breached Ignition sources can suddenly ignite these fuels Flammable vapors can be rele...

Страница 6: ...pect and properly maintain rescue equipment Inspect all rescue equipment after each use Any equipment found damaged or inoperable should be removed from service Storage of rescue equipment in adverse conditions Always store rescue equipment in clean dry and secure conditions Operation of rescue equipment with missing or illegible safety markings Modification of tools and power units inconsistent w...

Страница 7: ...e location providing master on off switch circuit controls low oil high temperature indicator lights The Human Machine Interface HMI display provides system operational information as well as input and output indicators to quickly troubleshoot the system An Ethernet interface provides a programming and troubleshooting connection for factory assistance should the need occur to interface to the powe...

Страница 8: ... 7 2021 Rev02 4 1 PART IDENTIFICATION Figure 4 1 Power Unit Wireless Remote Controls Receiver Reel Return Reel Pressure Reel Return Reel Pressure Sight Gauge Drain Plug Vent Cap Reservoir Fill Cap Oil Filter Heat Exchanger Inlet Power Plug Heat Exchanger Outlet ...

Страница 9: ...een or the button switches below the user may Start the system Operate either pump motor Open or close the pump valves See Section 9 0 on page 17 for detailed operating instructions I O Screen The I O screen shows the states of each input and output in real time This screen is most helpful for troubleshooting a system Runtime Screen The runtime screen shows total hours of use on each motor ...

Страница 10: ...tober 7 2021 Rev02 4 3 WIRING IDENTIFICATION Figure 4 3 Connection Callouts 1 Radio TR 2 HMI Ethernet C5 3 HMI POWER CONTROL HMI 4 OIL TEMP SENSORS LVTEMP 5 12VDC IN 12 IN 6 12VDC OUT 12 OUT 7 MOTOR 1 M1 8 MOTOR 2 M2 9 208 240VAC IN POWER 1 2 3 4 5 6 7 8 9 ...

Страница 11: ... Copyright AMKUS Rescue Systems 2020 2021 11 LAP 012 October 7 2021 Rev02 5 0 OVERALL DIMENSIONS Figure 5 0 ...

Страница 12: ... optional remote control system A VFD Variable Frequency Drive Panel B Control Panel C Heat Exchanger D Power Unit Figure 7 2A WARNING Tool operators bear responsibility for ensuring use of appropriate protective clothing and equipment The chosen protective clothing and equipment must provide protection from potential hazards users may encounter while operating AMKUS rescue tools Requirements for ...

Страница 13: ...being used be sure the pressure line has a male coupler at the end of the reel The return line will have a female coupler at the end of the reel If AMKUS Mono Couplers are being used be sure the pressure line is connected to the pressure port P of the female Mono Coupler and the return line is connected to the tank port T of the female Mono Coupler Figure 7 2 4 NOTICE Use of hydraulic fluids other...

Страница 14: ... control button Refer to the operating section of this manual for further explanation of button functions Mount the 240SS Control Panel in a compartment accessible to operators 7 2 7 VFD PANEL Mount the 240SS VFD Panel in a compartment Ensure the VFD can be accessed and the cover can be easily removed by maintenance technicians 7 2 8 WIRELESS REMOTE CONTROLS OPTIONAL 1 Mount the reciever in a comp...

Страница 15: ...N position by flipping each switch up 4 The upper section of the Control Panel houses the touch screen display and the touch display The green button is used to enable disable the entire unit Press the physical or digital green button to start the system The screen should indicate the system has started ON 5 Press the physical or digital blue M1 button to start Motor No 1 The screen should indicat...

Страница 16: ...id level continues to drop after several minutes check for fluid leaks 10 When finished shut the power unit off 11 Replenish hydraulic fluid until the sight gauge is completely full Pressure Line Fluid Flowing From The Pressure Line Return Line 12 To verify the pressure and return hoses remove both couplings from the end of the hoses and place the hose ends in a bucket 13 Charge the appropriate va...

Страница 17: ... to turn control valve off 9 2 2 OPERATING INSTRUCTIONS 1 Rotate the Emergency Stop 1 Red thumb wheel clockwise and release to ensure the remote is in the operation mode 2 Press and hold both start buttons at the bottom of the remote While holding the start buttons the remote is linking up to the receiver mounted in the apparatus Hold the start buttons pressed firmly to ensure a good signal 3 Push...

Страница 18: ...e hydraulic fluid to drain completely 5 Clean and reinstall the drain plug 6 Replace the filter 7 Fill the hydraulic fluid reservoir with new AMKUS MV1 fluid 8 Reinstall the fill plug vent cap 9 Cycle rescue tools several times to purge air from the hydraulic hoses 11 2 HYDRAULIC HOSES After each use hoses should be wiped clean with a light cleaner such as Simple Green Inspect hoses for damage to ...

Страница 19: ...een remaining dark after the unit is powered on and running Figure 11 4 1 Flip the PLC Run Stop switch to the Stop position 2 Power down the PLC completely 3 Use an insulated screw driver to pull out the battery holder from the PLC 4 Remove and replace battery with a quality BR2032 coin battery or equivalent Be sure the battery polarity is correct positive is indicated 5 Slide the battery holder i...

Страница 20: ...tool hoses fittings and couplings clean see routine maintenance for hoses and couplings 3 If the power unit becomes contaminated determine the nature of the contamination Follow the decontamination guidelines provided by the Authority Having Jurisdiction Technical advice may be requested from AMKUS Rescue Systems 4 Inspect the power unit hoses fittings and couplings after each use for damage leaka...

Отзывы: