©Copyright AMKUS Rescue Systems 2020-2021
17
LAP-012 October 7, 2021 Rev02
9.0 OPERATION
9.1 GENERAL
The 240SS is a simultaneous operation power unit. Two tools can be connected to a single power unit and operated either
independently or simultaneously. To operate the 240SS. Ensure there is power to the unit. Begin operation by pressing the system start
button. Then, press the motor button to begin building pressure. Once pressure builds, press the corresponding valve button to charge
the rescue tool for operation.
After completing operations, pressing the green start button turns the entire system off.
9.2 OPTIONAL WIRELESS REMOTE CONTROL
9.2.1 FEATURES
1.
Emergency Stop (Red)
- Closes both valves and powers down both motors. Press to active Emergency Stop. Rotate thumb
wheel clockwise to resume normal operation.
2.
Start Buttons (Green)
- Synchronizes the remote to the receiver and activates the system.
3.
M1 Motor Switch (Blue left side)
- Depress to activate motor for M1 circuit. Depress again to turn motor off.
4.
M2 Motor Switch (Red left side)
- Press to activate motor for M2 circuit. Press again to turn motor off.
5.
V1 Valve 1 Switch (Blue right side)
- Press to activate control valve for V1 circuit. Press again to turn control valve off.
6.
V2 Valve 2 Switch (Blue right side)
- Press to activate control valve for V2 circuit. Press again to turn control valve off.
9.2.2 OPERATING INSTRUCTIONS
1. Rotate the Emergency Stop (1) (Red) thumb wheel clockwise and
release to ensure the remote is in the operation mode.
2. Press and hold both start buttons at the bottom of the remote. While
holding the start buttons the remote is linking up to the receiver
mounted in the apparatus. Hold the start buttons pressed firmly to
ensure a good signal.
3. Push the M1 and/or M2 motor buttons (The motors are programmed
to reach full operating speed in 5 seconds).
4. Push the V1 and/or V2 valve button(s) to activate the appropriate reel
circuits.
5. To shut off a circuit, push the appropriate valve (5) and/or (6) button.
To quickly shut down the entire system including the power, motors and reel
circuits, push the Emergency Stop.
To re-activate the system, repeat these instructions starting at number 1.
10.0 TROUBLESHOOTING GUIDE
Table 10.0
PROBLEM
POSSIBLE REMEDY
Tool lacks power or speed
Check hydraulic fluid level in power unit reservoir.
Fluid leaks at fittings or hoses
Check tightness of hose fittings.
Replace damaged hoses.
Tools do not operate
Check to that the power unit is running.
Check that the line is charged.
Check hydraulic fluid level in power unit reservoir.
System turns on but screen is dark
Change the PLC battery
NOTICE
Immediately remove malfunctioning or damaged tools from service. Consult your dealer or AMKUS
Rescue Systems.
ALL SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE TECNICIANS IN OBSERVANCE OF
SAFETY REGULATIONS.
1
5
6
2
3
4
Figure 9.2.2