background image

12

   

  

Amico Corporation

Ordering Information

Parts list 

DESCRIPTION

MODEL NUMBER

Line pressure regulator for Oxygen, Nitrous Oxide, Medical Air, 

and Carbon Dioxide

M2-X-MAN-42E-EC 

Line pressure regulator for Nitrogen

M2-X-MAN-42E-ECN 

Left operating pressure regulator

M3-X-MAN-18-ECL

Right operating pressure regulator

M3-X-MAN-18-ECR

Line regulator repair kit

M2-REG700-RK

Operating regulator repair kit

M2-REG250-RK-HP

Operating check valve for all gases

M-X-MAN-33B

Line pressure relief valve for all gases except Nitrogen

M-X-IN-72W-075

Operating pressure relief valve for all gasses 
Line pressure relief valve for Nitrogen

M-X-IN-72W-225 

Operating Pressure relief valve for Nitrogen

M-X-IN-72W-350 

Copper pigtail, comes with check valve for Oxygen, Nitrous Ox-

ide, Carbon Dioxide and Nitrogen

M-X-HB-PTC-GAS (OXY, N2O, AIR, CO2 & NIT)

Stainless steel pigtail, comes with check valve for Nitrous Oxide, 

Carbon Dioxide and Nitrogen

M-X-HB-PTS-GAS (N2O, AIR, CO2 & NIT)

High pressure inlet header bar valve 

M-X-HB-HPVLV-A

Pressure switch

M-PRSW-NIT

M2-HBYY-XXL-GAS

“XX” Defines the Number 

of Cylinders:

04  =  2 x 2 
08  =  4 x 4 

“YY” Defines the Type of Header-Bar 

Assembly:

TS  =  Straight, comes with Stainless Pigtails
TC  =  Straight, comes withCopper Pigtails
XS  =  Staggered, comes with Stainless Pigtails
XC  =  Staggered, comes with Copper Pigtails

Manifold Cabinet:

Header-Bar Assembly:

M3EC-S-HH-L-GAS

HH  =  High Pressure

EC = Economy

S  =  Single Heavy Duty Line Regulator

“L” Defines the 

Language:

U  =  English (NFPA)
S  =  Spanish (NFPA)

The “GAS” Defines the

Type of Gas:

Oxygen 

= OXY

Nitrogen 

= NIT 

Medical Air 

=  AIR

Carbon Dioxide  =  CO2
Nitrous Oxide 

=  N2O

Wall Bracket for Header-Bar Assembly:

 

M-X-HB-WLBRKIT

Содержание Carbon Dioxide

Страница 1: ...Installation Maintenance Manual Economy Manifold...

Страница 2: ...m Systems 6 Safety Features 6 Installation 7 Receipt and Location 7 Cylinder Bank Installation Instructions 7 Operation Procedures 8 Maintenance 9 General Maintenance 9 Control Equipment 9 Cylinder Ex...

Страница 3: ...sembled operated maintained and serviced in accordance with the installation instructions provided The manifold MUST be checked periodically Parts that are broken missing worn distorted or contaminate...

Страница 4: ...zer informing the facility personnel that the In Use cylinder bank pressure is low and the cylinders need replacement At this point it is necessary to silence the alarm or buzzer and manually switch t...

Страница 5: ...ical Air and Carbon Dioxide service the line regulator should be set at 55 psig 379 kPa For Nitrogen service the regulator is set at 170 psig 1 172 kPa Pressure Relief Valves Pressure relief valves ar...

Страница 6: ...is a preset pressure switch Its function is to send a signal to the alarm unit when the operating pressure drops below its set point For Medical Air Oxygen Carbon Dioxide and Nitrous Oxide the pressur...

Страница 7: ...nder extension bar to the support using the U bolts supplied as part of the assemblies Remove the plug and chain assembly on each outlet connection on the cylinder extension bar Attach the cylinder pi...

Страница 8: ...to 140 psi decreasing pressure and will alarm when the In Use bank is depleted 5 To switchover simply move the lever from the depleted bank to the opposite bank to indicate the bank In Use This reset...

Страница 9: ...ng and closing the valve CYLINDER EXTENSION BARS The following components shall be inspected annually 1 Test check valves of pigtail assemblies for proper closure 2 Inspect pigtail assemblies for appa...

Страница 10: ...cap Worn out diaphragm Replace regulator with substitute unit or use repair kit to rebuild Venting at intermediate relief valve Over pressure due to creeping or faulty regulation by pressure regulator...

Страница 11: ...en the cylinder valve on the cylinder closest to the control cabinet Watch the bank pressure display on the front of the cabinet to make sure the pressure rises slowly to the full cylinder pressure re...

Страница 12: ...s with check valve for Oxygen Nitrous Ox ide Carbon Dioxide and Nitrogen M X HB PTC GAS OXY N2O AIR CO2 NIT Stainless steel pigtail comes with check valve for Nitrous Oxide Carbon Dioxide and Nitrogen...

Страница 13: ...MANIFOLD INTERNAL LAYOUT Pressure Switch Left Bank Gauge Left Bank Regulator Right Bank Gauge Right Bank Regulator Line Relief Valve Line Gauge Line Regulator Lower Pressure Gauge Operating Relief Va...

Страница 14: ...ndix B MANIFOLD DIMENSIONS Installation Mounting holes are 13 and 15 33 02 cm and 38 1 cm apart at the top and bottom of the back plate Use appropriate anchors supplied by others 3 8 9 525 mm diameter...

Страница 15: ...co com 15 WIRING TO ALARM BUZZER Appendix C Inch mm Power Alarm Mute Test Medical Gas Alarm Alert MEDICAL SUPPLY STATUS Power Maintenance Optional Monitoring Devices Master Alarm Remote Buzzer 7 75 19...

Страница 16: ...ay Richmond Hill ON L4B 2N4 Canada 71 East Industry Court Deer Park NY 11729 USA Toll Free Tel 1 877 462 6426 Tel 905 764 0800 Fax 905 764 0862 Email info amico com www amico com ACP INSTALL MAINT ECO...

Отзывы: