33
TRANSPORTING AND STORAGE
1. Be sure the storage area is free of excessive humidity and dust.
2. Service according to the table below:
When transporting the generator, turn the engine switch and the fuel valve
OFF. Keep the generator level to prevent fuel spillage. Fuel vapor or spilled
fuel may ignite.
Contact with a hot engine or exhaust system can cause
serious burns or fires. Let the engine cool before transporting or
storing the generator.
WARNING
!
Take care not to drop or strike the generator when transporting. Do not
place heavy objects on the generator.
Before storing the unit for an extended period:
Fill with fresh gasoline and add gasoline
conditioner*.
Drain the carburetor float bowl.
Drain the fuel sediment cup.
Remove the spark plug. Put a tablespoon of engine
oil into the cylinder. Turn the engine slowly with the
pull rope to distribute the oil. Reinstall the spark plug.
Change the engine oil
After removal from storage, drain the stored gasoline
into a suitable container, and fill with fresh gasoline
before starting.
STORAGE TIME
RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING
Less than 1 month
1 to 2 months
2 months to 1 year
No preparation required
Fill with fresh gasoline and add gasoline
conditioner*.
Fill with fresh gasoline and add gasoline
conditioner*.
Drain the carburetor float bowl.
Drain the fuel sediment cup.
* Use gasoline conditioners that are formulated to extend storage life.
Contact your authorized AMICO generator dealer for conditioner
recommendations.
1 year or more
Содержание AH7500E
Страница 1: ......
Страница 11: ...10 MUFFLER FUEL TANK CAP FUEL METER RECOIL STARTER GRIP SPARK PLUG CAP ...
Страница 40: ...39 ...
Страница 41: ...40 DETAIL DIAGRAM ...
Страница 44: ...43 PANEL DETAIL DIAGRAM ...
Страница 46: ...45 WIRING DIAGRAM ...