The Oil Alert system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the
crankcase can fall below a safe limit, the Oil Alert system will automatically
shut down the engine (the engine switch will remain in the ON position).
The circuit breaker will automatically switch OFF if there is a short circuit or
a significant overload of the generator at the receptacle. If the circuit
breaker is switched OFF automatically, check that the appliance is working
properly and does not exceed the rated load capacity of the circuit before
switching the circuit breaker ON again.
CIRCUIT BREAKER
GROUND TERMINAL
The generator ground terminal is connected to the frame of the generator,
the metal non-current carrying parts of the generator, and the ground
terminals of each receptacle.(see next page)
OIL ALERT SYSTEM
PILOT LAMP
The pilot lamp is illuminated when the generator is operating normally.
ON
OFF