background image

5

2. Reattach the air cleaner cover and screw
   on the wing nut.

The generating set should be earthed to
prevent electdc shocks.

3.4 Check the generating set

1. Turn off the main switch and any other
   loads.

Be sure to turn offthe main switch before
starting.
The generating set should be earthed to
prevent electric shocks.

!

WARNING

!

WARNING

Elelment

Low oil warning lamp

AC output receptacle

Ground terminal

Ground terminal

Содержание AH6000LN

Страница 1: ......

Страница 2: ...perate it according to the manual instruction Otherwise serious personal injury and equipment damage will result So AMICO reconfirms that ou must to read and understand this manual before operating th...

Страница 3: ...ted locations If it s necessary to run the generating set indoors be sure to provide the ad equate ventilation 3 BE CARE NOT TO BE SCALDED The muffler and the engine body are very hot while the engine...

Страница 4: ...in injuries and accidents Be sure to discon nect any apparatus from the generating set or prior to starting Most appliance motors require more than their rated wattage for start up Do not exceed the...

Страница 5: ...Generating Set Operate the Generating Set Load Stop the Generating Set Periodic Checks and Service Long term Storage Troubleshooting and Remedy Detail Diagram Panel Detail Diagram Wiring Diagram LIMI...

Страница 6: ...d r min Power factor cos Excitation mode DC output Operation mode Coupling method Engine Model Gross weght kg Overall dimensions LxWxH mm AH6000LN Generator 60 6 0 120 240 50 25 3600 1 12V 8 3A 12 hou...

Страница 7: ...2 Outlet fo cooling air Fuelfiller cap Lifting eye Low oil pressureg lamp Exhaust AC output DC output Engine starter switch 2 CONFIGURATION 2 1 Parts name...

Страница 8: ...will result Do not overdill Overfilling is very dangerous De not fill the tank beyond the top of the red plug inside the fuel oil fillter 3 PREPARATION FOR STARTING WARNING Refuel in a well ventilate...

Страница 9: ...stops the engine automatically when the oil level falls below the lower level This prevents accidents such as bearing seizures etc Select the most applicable engine oil It is very important to select...

Страница 10: ...t electdc shocks 3 4 Check the generating set 1 Turn off the main switch and any other loads Be sure to turn offthe main switch before starting The generating set should be earthed to prevent electric...

Страница 11: ...hould always be kept in the ON position during operation Before starting the engine be sure to turn the switches of the working instru ment lighting apparatus motor etc to their OFF position If the sw...

Страница 12: ...period Replace the engine oil on time Replace the engine oil while the engine is warm after 20 hours running the old engine oil will be drained out completely Approx one month or 20hours Every 3 mont...

Страница 13: ...ore start ing it again 1 Starting Open the fuel cock Set the engine speed lever at RUN position Run the starting motor for long time will cost the battery power greatly even burn out the molor Always...

Страница 14: ...same with generator s anode cathode line check volt if it is 12 3V otherwise must electricize 2 every month check volt if it is right free charge maintenance battery s charge volt is 13 5V 14 5v 3 che...

Страница 15: ...just either the engine speed limiting bolt or fuel injection limiting bolt otherwise the performance will be affected 5 2 Checks during the running 1 Whether there is abnormal sound or vibration 2 Whe...

Страница 16: ...quipment to the generating set in order Forthematterofthemotor load firsPy the heavy duty motor should be connected then the light duty motors If the operation is false the generating set will lag or...

Страница 17: ...ged excessive current flows the fuse for the direct current will burn out Do not run the generating set while it is still connected with the battery Do not use DC12V and AC at the same time CAUTION Ba...

Страница 18: ...s to the generator set 300VA TYPE WATTAGE STARTING RATED TYPICAL APPLIANCE EXAMPLE APPLIANCE STARTING RATED Incande scent lamp Heating applian ce Xl Xl Incandescent lamp TV 100W I00VA W I00VA W Fluore...

Страница 19: ...r of the generating set 3 Set the speed lever at RUN position run the generating set without load for about 3 minutes Do not stop the engine suddenly otherwise the temperature will increase abnormally...

Страница 20: ...eakage Check and tighten fasten ing parts bolts Tighten the Cylinder head Replace engine oil First time Secondtime Clean engine oil filter Replace if necessary Replace air cleaner element Service more...

Страница 21: ...500 hours Replace if necessary 8 3 Replace the air cleaner element Do not clean the air cleaner element with detergent Replace time Every 6 months or 500 hours Never run the engine without the elemen...

Страница 22: ...from the filler port 3 Wash the filter thoroughly with diesel fuel Loosen the fastening nut bottom cover and delivery discs for cleaning the deposit carbon 8 5 Tighten cylinder head bolt Tightening t...

Страница 23: ...riods make the following preparations 1 Operate the engine for about 3 minutes and then stop 2 Stop the engine Drain the engine oil while the engine is still warm and fill with fresh oil 18 Oil filler...

Страница 24: ...Remove the nozzle and repair it at test table Set the leverto START position The specified oil level should be between the upper level and lower level Clean the nozzle Start the engine according to th...

Страница 25: ...20 11 DETAIL DIAGRAM...

Страница 26: ...21...

Страница 27: ...is Rolling Wheel On Chassis Flat Key Pin Motherboard Of Accumulator Accumulator Bolt Number Part Description Quantity Part Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 2...

Страница 28: ...lt M6 12 Bolt M10 45 Bolt M6 16 Bolt M8 25 Bolt M6 12 Bolt M5 8 Bolt M6 Nut M8 Nut Flat Spring Washer M10 Nut Flat Spring Washer M5 12 Bolt M6 22 Bolt 46 47 48 49 50 51 52 53 54 55 56 57 58 1 1 1 1 1...

Страница 29: ...24 12 PANEL DETAIL DIAGRAM...

Страница 30: ...LN088 AH6000LN089 AH6000LN090 AH6000LN091 AH6000LN092 AH6000LN093 Panel M6X12 Bolt Starter Switch M4X30 Bolt 3 Prong Socket M4X15 Bolt M5X25 Bolt Positive DC Port Negative DC Port Grounded Bolt Integr...

Страница 31: ...26 13 WIRING DIAGRAM...

Страница 32: ...ted warranty shall be final This warranty does not cover 1 Merchandise sold as reconditioned used as rental equipment or floor or display models 2 Merchandise that has become damaged or inoperative be...

Страница 33: ...Gregg Road Pico Rivera CA 90660 U S A Tel 562 908 0088 Fax 562 908 1899 Website www amicousa com Model No Engine Serial No Purchase Date Purchased from Retail location Private Consumer Other Name Add...

Страница 34: ...ccupation Place of purchase Packaging conditions Operating conditions Parts Conditions Malfunction problem Opinions or suggestions Note Please mail the above card to Amico International Corp 4825 Greg...

Страница 35: ...Air cooled Diesel Generator Set Kit Plastic cover Plug and power supply 1 2 3 4 5 1 1 1 1 2 Attached technical documents Order No Name Qty Remarks 1 1 1 1 1 1 2 3 4 Air cooled diesel generator manual...

Отзывы: