7
INSTALLATION
Installation of the ventilation hood in the exhaust mode
(extracting of used air to the outside)
1. Fix the wall section of the ventilation hood to the wall, using fixing pins and screws
from the installation packet, at a height so that the suspended ventilation hood in on
the level of 650-750 mm over the top of the stove.
2. Remove the fat filter of the ventilation hood (the number of filters
depends on the type of the hood) by unfastening the snap fastener.
3. The hood must be placed with its installation opening in the back
against the wall over the installed wall section so that the upper edge of
the opening slides into the wall section (see the drawing beside).
4. The ventilation hood should then be leveled using a hand level and, if necessary,
its position should be corrected by screwing in or out of the leveling screws located
on the body of the hood over the installation opening. After the ventilation hood is
leveled, a securing screw should be screwed in in the middle of the wall section.