TROUBLESHOOTING

 

 
Before beginning any troubleshooting, carefully read the safety instructions in chapter 2 of this document and make sure that all the 
workers at the filtration site are fully aware of and comply with, these and any other local safety instructions.    
 
The filtration system may enter a malfunction mode in the following cases: 

 

Symptom 

Remarks and Actions 

Fault due to continuous signal from the 
pressure differential switch for duration of 
more than 15 minutes. 
 
The fault indication lamp is lighted in red 

This fault means that the self-cleaning process is not successful. 
 
This fault may be caused by one of  the following reasons: 
 

A.

 

The filter is clogged due to heavy dirt load or too high water flow rate. 

Close the filter’s downstream valve.

 

Press the reset button to reset the fault mode. The fault indication lamp 
is turned off. 
Perform few consecutive manual flush cycles and monitor the PD signal. 
Once the filter is clean gradually open the downstream valve and 
monitor the PD and the flow-

rate. Make sure that the filter doesn’t 

exceed its designated flow-rate.  

B.

 

The PD switch is faulty. 
Ask your qualified electrician to check the PD connections and operation. 
Replace the switch if found faulty.    

 

The motor protector was activated 
 
The fault indication lamp is blinking in red 

This fault means that the motor was operated under too high load 
 

Note:

 All the following checks and actions should be done by a qualified electrician 

only. 
 

A.

 

Check the motor power consumption when not loaded. 

B.

 

 Check the limit switches for correct operation and verify that each one of 
them stop the motor at its designated point. 

C.

 

Verify 3 phase 380VAC power supply to the control board and the motor. 

D.

 

Disconnect the drive unit from the suction scanner shaft and verify free 
turning of the suction scanner. 
 

Note:

 If during this fault a request for flushing is received (Manual, Time or DP) the 

blinking lamp switches to constant red. 

 

Malfunctioning limit switches  
 
The fault indication lamp is blinking in red 

Faulty limit switch may not stop the motor at the right point and therefore the motor 
protection may be activated. 
Receiving signal from both limit switches at the same time causes fault 
 

A.

 

Check that the limit switches are not mechanically stuck. 

B.

 

Ask your qualified electrician to check the wiring and the functionality of the 
limit switched. 

 

Note:

 If during this fault a request for flushing is received (Manual, Time or DP) the 

blinking lamp switches to constant red. 

   

The fault indication lamp is blinking in red 
after the reset button is pressed 
 

This means that the mechanical/electrical fault still exists. (Overload or Limit 
Switches faults) 
 

 

Содержание EBS-10000

Страница 1: ...01 000109 09 17 Page 1 of 24 AMIAD WATER SYSTEMS EBS 10 000 IN LINE FILTER Serial number Order number Catalogue number Filtration degree Tested by Installation Operation and Maintenance Instructions 910101 000109 09 17 ...

Страница 2: ... content The confidential nature of and or privilege in the file enclosed is not waived or lost as a result of a mistake or error in this file If you received this file in error please notify Amiad immediately at info amiad com This document does not replace any certified drawing procedure or information provided by Amiad in reference to a specific customer site or project Amiad assumes that all u...

Страница 3: ... 8 Description and filter operation 9 Installation 10 Commissioning Start up and First Operation 11 Maintenance 12 Troubleshooting 14 Disassembling and reassembling 15 Parts schedule 18 Parts drawing Section 1 20 Parts drawing Section 2 21 Parts drawing Section 3 22 Limited Warranty 23 With any inquiry please quote Filter Serial Number located on the filter housing ...

Страница 4: ... Flush data Exhaust valve 80mm 3 Flushing cycle time 30 40 seconds 30 40 seconds Wasted water per cycle 500liter 132USgal at 2bar 30psi Minimum flow for flushing 50m h 220USgpm at 2bar 30psi Control and electricity Electric motor 1 2 HP 50 60 Hz 18 22 Gear output R P M Rated operation voltage 3 phase 220 380 440 V 50 60 Hz Single phase 110 220 V 50 60 Hz Control voltage 24V AC Current consumption ...

Страница 5: ...ting at the area of the filter to enable good visibility and safe maintenance The user should arrange suitable platforms ladders and safety barriers to enable easy and safe access to the filter without climbing on pipes and other equipment The user should verify that any platform barrier ladder or other such equipment is built installed and used in accordance with the relevant local authorized sta...

Страница 6: ... note that the maximum working pressure indicated at the filter s specifications table includes the pressure caused by fluid hammer and pressure surge effects Civil Engineering Make sure that the filter installation is done by Amiad qualified technicians Make sure that any civil engineering work at the installation site such as construction lifting welding etc is done by qualified workers technici...

Страница 7: ...ze slippage electrification or damage to the equipment caused by moisture While using lifting equipment make sure that the filter or the lifted part is chained securely and in a safe manner Do not leave lifted equipment if there is no necessity Avoid working below lifted equipment Wear a safety helmet goggles gloves and any other personal safety equipment required by the local standards and regula...

Страница 8: ...EBS 10000 IL 910101 000109 09 17 Page 8 of 24 DIMENSIONAL DRAWING ...

Страница 9: ...e timer in the control board to CONT position 4 Malfunction mode During malfunction mode the self cleaning operation is stopped the malfunction light on the control board is turned on and an external output is activated with 24V AC The filtration system may enter a malfunction mode in the following cases 1st When there is a continuous signal from the pressure differential switch for duration of mo...

Страница 10: ...remove large objects that may damage the filter s internal mechanism 7 Install a drainage pipe to the exhaust valve Minimum 3 diameter for a maximum pipe length of 20 meters 60 feet for longer drainage 4 pipe diameter must be used for a maximum length of 40 meters 120 feet Please note that no restriction is allowed on the drainage pipe For special applications please consult the manufacturer 8 If ...

Страница 11: ...ntrol 24V circuit breakers and the motor protector to ON The motor will start operating The suction scanner shaft should turn clockwise and move downward to the filter housing until it reaches the lower limit switch If the motor rotates in the opposite direction disconnect the electricity immediately and change the direction of the motor rotation by changing between two phases The motor must stop ...

Страница 12: ...e filter carefully and safely to its water air and power supply 7 Perform a General Inspection of the Filter Operation as described above Changing the sealing flange internal O ring 1 Close the inlet valve to the filter and release any residual pressure 2 Disconnect and lock the filter s power supply 3 Disconnect and lock the filter s compressed air supply and release any residual pressure 4 Verif...

Страница 13: ...ter housing or accessories h Unusual vibrations i Non smooth operation of the filter valves air release valves and check valves 2 Close the inlet and the outlet valves of the filter Drain the filter housing and release any residual pressure 3 Disconnect and lock the filter s power supply 4 Disconnect and lock the filter s compressed air supply and release any residual pressure 5 Disassemble the fi...

Страница 14: ...if found faulty The motor protector was activated The fault indication lamp is blinking in red This fault means that the motor was operated under too high load Note All the following checks and actions should be done by a qualified electrician only A Check the motor power consumption when not loaded B Check the limit switches for correct operation and verify that each one of them stop the motor at...

Страница 15: ...58 then pull out the connecting pin If the connecting pin is not facing one of the shaft housing windows turn the drive shaft 56 a little Use 17mm or 11 16 spanners 7 Turn the drive shaft 56 counter clockwise so that it will be separated from the suction scanner shaft 12 8 Unscrew bolts 61 and remove the limit switches sling without disconnecting and changing the limit switches position 9 Unscrew ...

Страница 16: ...uld be lifted only with Amiad s standard Extractor and a standard lifting device operated by an authorized operator 1 Clean and dry the rubber pads on the Extractor 2 Fold the Extractor upwards Figure 1 Figure 1 3 Insert the Extractor into the screen about a quarter from top Make sure that the extractor cushions do not touch the stitch found along the screen interior 4 Pull the extractor up so tha...

Страница 17: ...with two bolts 22 in opposite positions 6 Screw the rest of the housing bolts 22 Tightening opposite positioned bolts will achieve proper sealing 7 Locate the O ring 23 in its groove under the shaft housing 24 Place the bolts 25 but do not yet tighten them firmly 8 Turn the drive shaft 56 clockwise until it reaches the suction scanner shaft Insert the connecting pin 58 into the hole in the drive s...

Страница 18: ... NBR N F 1 24 710105 001473 DR SHAFT HOUS EBS 10K EPOXY PKPK 3002 1 25 760101 000328 HEX BOLT PARTIAL THR M16X60 Z PLT C ST 8 26 760103 000069 FLAT WASHER M16 DIN125 ZINC PLATED C ST 16 27 760102 000067 HEX NUT M16 ZINC PLATED C ST DIN934 8 28 710105 001474 DR SHAFT HOUS COVER EBS EPOXY PKPK 3002 1 29 720202 000018 GEAR RMI70 FL 1 70 71 B5 1 30 760101 000314 HEX BOLT FULL THRD M10X40 Z PLT C ST 4 ...

Страница 19: ...X16 S ST304 DIN916 2 74 760101 000527 SOCKET SET SCREW M10X50 S ST316 DIN916 2 75 760103 000097 FLAT WASHER M10 DIN125 S ST316 2 76 760102 000087 HEX NUT M10 S ST316 DIN934 2 77 700190 002336 MANOMETER VALVE 1 4 W DRAIN 1 78 720501 000214 T CONNECTOR1 4 FX1 4 FX1 4 M NICKEL PLA 2 79 720501 000202 L CONNECTOR 5 16 X1 4 69F BRASS 2 80 730104 000202 VALVE 3 WAY 1 4 SAGIV SY3 1Y3NO4OA4 1 81 720501 000...

Страница 20: ...EBS 10000 IL 910101 000109 09 17 Page 20 of 24 PARTS DRAWING Section 1 ...

Страница 21: ...EBS 10000 IL 910101 000109 09 17 Page 21 of 24 PARTS DRAWING Section 2 ...

Страница 22: ...EBS 10000 IL 910101 000109 09 17 Page 22 of 24 PARTS DRAWING Section 3 ...

Страница 23: ... This warranty is valid on the condition that the Products are installed according to Amiad s instructions as expressed in Amiad s instruction manuals and according to the technical limitations as stipulated in Amiad s literature or as stated by a representative of Amiad 7 This warranty will not apply to damaged or defective Products resulting from or related to i Fire flood power surges or failur...

Страница 24: ...233500 Israel Tel 972 4690 9500 Fax 972 48141159 Email info amiad com Obelis s a Bd Général Wahis 53 1030 Brussels Belgium Tel 32 2732 5954 Fax 32 27326003 Email mail obelis net EC Declaration http amiad com pdf certificates MACHINERY_SAFETY pdf ...

Отзывы: