22022626 Rev A
24
NGX Ultra Jukebox
Recommended Routine Maintenance
Heat is the biggest enemy of electronic
components. Proper maintenance is essential for
maximum earnings and reliability.
It is very important to keep all cooling fans clean.
Once dust and dirt is visible on a cooling fan, the
airflow can be reduced by 25% or more. There are
several cooling fans in the cabinet (see
Figure 1-D
).
Recommended preventative maintenance
Routine Service
The following steps take about 3 minutes and should
be performed at each collection.
1. Check the CPU fan from the “Health Status”
Screen.
2. Ensure the cabinet fans at the upper-right top
of the cabinet are blowing air out and the fans
look clean. (See
Figure 1-D
).
3. Be sure that nothing is resting on top of the unit
or otherwise blocking the airflow around the
machine.
Figure 1-D – Inside View of Cabinet
Collecting from the Bill Acceptor
1. Unlock and open the front door.
2. To remove the bill stacker, slide the tab on the
bottom of the bill acceptor towards the front
door, push the stacker downward then pull it off
the bill acceptor.
3. Open the side door on the bill stacker to
remove the cash.
4. Push the Service button to access the Collect
Now function to help manage and audit your
collections.
5. Slide the bill stacker back on the bill acceptor.
Be sure the green light is on (for MEI, make
sure the green lights/arrows are flashing).
6. Close and lock the jukebox door.
Minor Service
Perform these steps a minimum of every 3 months if
operating more than 14 hours per day, operating
where smoking is allowed, or operating in a dusty
environment. Perform these steps a minimum of
every 6 months if operated less than 14 hours per
day and in a very clean environment. You will need a
new, soft 2” paintbrush*.
1. Gently brush* dirt from the cabinet cooling
fan. Verify fan operation.
2. Check the operation of the CPU fan from the
“Health Status” Screen.
3. Listen to the CPU fan for excessive noise or
vibration. Replace faulty fans as needed.
4. Clean the bill acceptor with an approved
cleaning card.
5. Clean the credit card reader with an
approved cleaning card.
6. Clean then calibrate the touchscreen (see
the next page for calibration instructions).
Cleaning the Touchscreen
Any standard glass cleaner can be used to clean the
touchscreen. Always spray the glass cleaner on the
cloth or towel and not directly on the touchscreen.
Glass cleaner sprayed directly on the screen could
possibly leak inside and cause damage.
Cleaning the Currency Panel
The door panel is made of plastic. We recommend
cleaning with a mild cleaner and a soft cloth to avoid
scratching the surface.
Annual Service
The following steps should be performed every year
in addition to everything in the minor service section.
1. Vacuum the interior of the cabinet and fans.
2. Inspect the power cord for fraying or damage.
3. Check the power ground.
4. Check all LAN connections and wiring.
5. Listen to all speakers to make sure they are
operating correctly.
Scheduled
maintenance
always
costs less time
and money than an unscheduled breakdown.
Содержание NGX ULTRA
Страница 6: ...22022626 Rev A 4 NGX Ultra Jukebox This page is intentionally left blank ...
Страница 25: ...NGX Ultra Jukebox 23 22022626 Rev A Section D Service Maintenance Recommended Routine Maintenance ...
Страница 28: ...22022626 Rev A 26 NGX Ultra Jukebox This page is intentionally left blank ...
Страница 40: ...22022626 Rev A 38 NGX Ultra Jukebox This page is intentionally left blank ...
Страница 50: ...AMI Entertainment Network LLC 4147 Eastern Avenue SE Grand Rapids Michigan 49508 ...