15
96
97
95
94
1. Connecting wire with control box
(See Fig. 24)
.
Note: 1) Specification of wire of limit switch and Air solenoid valve is 2
×
1
2
2) Wire cable for power source and motor are 4
×
2.5
2
3) Using white bobbin to wind around wire.
2. Adjusting the current rating of thermal relay in control box according to the different
configurations of hydraulic power unit. In general, the electric current of thermal relay
should equal or larger than that of motor. The following table shows rated current
regulation of thermal relay in case of different hydraulic power unit.
Hydraulic power
unit
PEAK
SPX
220V
3HP
380V
3HP
415V
3HP
220V
3HP
380V
3HP
Rated current of
thermal relay
16A
12A
12A
18A
12A
Connecting wire of
Hydraulic Solenoid
Valve
Connecting wire of limit
switch
Connecting wire of
motor
Connecting wire of
power
Fig. 24
Содержание A245LX
Страница 1: ...TWO POST LIFT Model A245LX...
Страница 4: ...2 Arm Swings View For Model A245LX Fig 2...
Страница 10: ...8 F Assembly oil hose assy See Fig 15 Fig 14...
Страница 11: ...9 2 Push the carriages to the bottom of the columns See Fig 16 Fig 15 77 80 77A 77 75A 76 77 77 75...
Страница 25: ...23 Model A245LX Cylinders Fig 38 Car in...
Страница 26: ...24 Control Box SPX ELECTRIC POWER UNIT 220V 50HZ single phase Fig 39 Fig 40...