Ethernet Operation
In order for the AMG system to transmit Ethernet signals, an onboard RJ45 Ethernet interface or
X16003 Ethernet interface adaptor should be fitted to both the Transmit unit and the Receive unit.
The Ethernet interface can operate at either 10Mbits/s half duplex, or 100Mbit/s full duplex, and data is
transmitted from one port the other port with the minimum of delay or buffering. The maximum
bandwidth (at 100Mbit/s full duplex) available for transmission across the fibre link is nominally
50MBit/s.
The 100BaseT port does not implement MDI/MDIX; it should be connected with a straight though
cable to an external switch port and with a cross over cable when connected directly to a PC or DTE.