background image

 

Seite 1 von 10 

AMG Sicherheitstechnik GmbH 

 Industriepark Straße A-9 

 39245 Gommern 

 fon 039200-7797-0 

 Freecall 0800-2264264* 

  

fax 039200-7797-29 

 

www.amg-sicherheitstechnik.de

 

 

[email protected]

 

 

Business hours are 9-17 clock, outside this time an answering machine is running 

*) Free from landlines and all German mobile networks 

 

 
 
 

22/12/2014 (18)

 

 

 

 
 

 

1. Program a smoke detector .............................................................................................................. 2 

2. Delete all smoke detectors .............................................................................................................. 2 

3. End of an alarm ............................................................................................................................... 3 

4. Specifications headquarters ............................................................................................................ 3 

5. User manual smoke detector .......................................................................................................... 4 

Mounting location ............................................................................................................................... 4 

Assembly of the magnetic pads .......................................................................................................... 5 

Planning / Installation ......................................................................................................................... 7 

Installation ........................................................................................................................................... 7 

Operation of the smoke detector........................................................................................................ 7 

Maintenance / Repair .......................................................................................................................... 8 

Battery change .................................................................................................................................... 8 

Summary DIN EN 14604 ...................................................................................................................... 9 

Re-order Smoke detectors ................................................................................................................ 10 

 
 
 
 

Note: Please arm the alarm unit first! 

 

 

User manual fire alarm set

 

Содержание BMS 03

Страница 1: ...ee from landlines and all German mobile networks 22 12 2014 18 1 Program a smoke detector 2 2 Delete all smoke detectors 2 3 End of an alarm 3 4 Specifications headquarters 3 5 User manual smoke detec...

Страница 2: ...by the unit 1 4 You now send the signal of the smoke detector twice by pressing the Test button on the smoke detector until it starts to beep and from the panel also comes a short beep Please repeat...

Страница 3: ...vice In addition you have the option of the siren either ON or OFF For this purpose press the RESET button The BUZZ button is to stop only the internal signal generator Note The yellow LED on the pane...

Страница 4: ...al and audible indication when battery replacement is required The minimum equipment of smoke detectors required are in the nursery sleeping area and hallway An optimum is if every room is equipped wi...

Страница 5: ...a max width of 3m the allowed distance between two smoke detectors is max 15 m The distance from one end of the corridor or passage to the other must not exceed 7 5m Smoke detectors in draughty points...

Страница 6: ...plied as described in the standard DIN EN 14604 will be able to work both as an individual detector as well as with other smoke detectors in an network A network requires special detectors such as tho...

Страница 7: ...rooms heating and work rooms and attic In stairwells or rooms with a gallery is at least to install one smoke detector on the top of the floor Better however would be a smoke detector on each level I...

Страница 8: ...ke detector is not damaged Deficiencies in these points should be removed immediately a damaged smoke detector must be replaced immediately The functional test of the smoke detector is to test the ala...

Страница 9: ...w amg sicherheitstechnik de info amg sicherheitstechnik de Business hours are 9 17 clock outside this time an answering machine is running Free from landlines and all German mobile networks Summary DI...

Страница 10: ...f the smoke detector using test facility to check In addition instructions must be provided for the mounting location installation and maintenance In addition on the product must be the symbol for the...