Ametek TESEQ KEMA 801A Скачать руководство пользователя страница 3

3

85-238526 E02

CONTENT

1. 

Safety advice ........................................................................................................................ 5

1.1. General ...................................................................................................................................................... 5
1.2. Installation ................................................................................................................................................. 5
1.3. 

Applicable safety standards ..................................................................................................................... 5

2. 

Unpacking, storage and transport ....................................................................................... 6

2.1. General ...................................................................................................................................................... 6
2.2. 

Storage and transport .............................................................................................................................. 6

2.3. Unpacking ................................................................................................................................................. 6
2.4. 

Scope of delivery and order information ................................................................................................. 6

3. 

Application and standard requirements .............................................................................. 7

3.1. General ...................................................................................................................................................... 7
3.2. 

Test set-up example ................................................................................................................................. 7

4. 

Verification of the insertion loss .......................................................................................... 8

5. 

Construction of the product................................................................................................. 9

6. 

Technical specification ....................................................................................................... 10

7. Maintenance ....................................................................................................................... 11

7.1. General .................................................................................................................................................... 11
7.2. Cleaning .................................................................................................................................................. 11

8. Disposal ............................................................................................................................... 11

Содержание TESEQ KEMA 801A

Страница 1: ...USER MANUAL RF ATTENUATION CLAMP KEMA 801A...

Страница 2: ...USER MANUAL RF ATTENUATION CLAMP KEMA 801A...

Страница 3: ...1 General 6 2 2 Storage and transport 6 2 3 Unpacking 6 2 4 Scope of delivery and order information 6 3 Application and standard requirements 7 3 1 General 7 3 2 Test set up example 7 4 Verification...

Страница 4: ...4 KEMA 801A...

Страница 5: ...rongly recommended Operate the equipment only in dry surroundings Allow any condensation that occurs to evaporate before putting the instrument into operation Do not exceed the permissible ambient tem...

Страница 6: ...upwards Protect from dampness heat cold and rain Do not throw Do not sit or stand on the instrument and packaging 2 3 Unpacking Is the packaging damaged If YES transportation company Are all the pack...

Страница 7: ...p example The following figure shows a test set up example for testing in accordance with IEC 61000 4 6 EN 61000 4 6 Figure 1 Test set up with EUT according IEC EN 61000 4 6 with EM clamp KEMZ 801 RF...

Страница 8: ...gure 3 Set up for measuring the insertion loss 2x 10 dB attenuator RF OUT 50 RF IN 50 NETWORK ANALYZER USB USB Power Tuning Back 0 1 4 7 8 5 2 3 kHz dBm 6 9 MHz dB V Hz V Enter StSize StSize StSize St...

Страница 9: ...9 85 238526 E02 5 CONSTRUCTION OF THE PRODUCT Figure 4 View to the opened KEMA 801A Ferrite cores spring loaded Mechanical interlock adjustable Figure 5 Side view...

Страница 10: ...79 mm Weight approx 5 5 kg Environmental classification Indoor use only Operating temperature 5 C to 40 C Relative humidity up to 80 Typical insertion loss in 50 system 0 0 10 20 40 30 60 50 0 1 1 10...

Страница 11: ...ries by the user 7 2 Cleaning The cleaning shall be done with dry cloth If a wed cleaning would become necessary make sure that no humidity gets inside the unit and clean the instrument housing with a...

Страница 12: ...rise Shanghai Co Ltd Beijing Branch T 8610 8526 2111 F 8610 8526 2141 chinasales teseq com Germany Teseq GmbH T 49 30 5659 8835 F 49 30 5659 8834 deinfo teseq ametek com Singapore AMETEK Singapore Pte...

Отзывы: