85-238526 E02

7. MAINTENANCE

7.1. General

The KEMA 801A needs no special maintenance. The maintenance is limited to the cleaning of the ferrite 
contacts.   

No modifications are to be carried out on the KEMA 801A and accessories by the user. 

7.2. Cleaning

The cleaning shall be done with dry cloth. If a wed cleaning would become necessary, make sure that no 
humidity gets inside the unit and clean the instrument housing with a damp cloth using a little mild, nonabrasive 
household cleanser if necessary.

Chemicals must not be used for cleaning purposes.

8. DISPOSAL

The unit is constructed that it can be dismantles right down to the component level.

Содержание TESEQ KEMA 801A

Страница 1: ...USER MANUAL RF ATTENUATION CLAMP KEMA 801A...

Страница 2: ...USER MANUAL RF ATTENUATION CLAMP KEMA 801A...

Страница 3: ...1 General 6 2 2 Storage and transport 6 2 3 Unpacking 6 2 4 Scope of delivery and order information 6 3 Application and standard requirements 7 3 1 General 7 3 2 Test set up example 7 4 Verification...

Страница 4: ...4 KEMA 801A...

Страница 5: ...rongly recommended Operate the equipment only in dry surroundings Allow any condensation that occurs to evaporate before putting the instrument into operation Do not exceed the permissible ambient tem...

Страница 6: ...upwards Protect from dampness heat cold and rain Do not throw Do not sit or stand on the instrument and packaging 2 3 Unpacking Is the packaging damaged If YES transportation company Are all the pack...

Страница 7: ...p example The following figure shows a test set up example for testing in accordance with IEC 61000 4 6 EN 61000 4 6 Figure 1 Test set up with EUT according IEC EN 61000 4 6 with EM clamp KEMZ 801 RF...

Страница 8: ...gure 3 Set up for measuring the insertion loss 2x 10 dB attenuator RF OUT 50 RF IN 50 NETWORK ANALYZER USB USB Power Tuning Back 0 1 4 7 8 5 2 3 kHz dBm 6 9 MHz dB V Hz V Enter StSize StSize StSize St...

Страница 9: ...9 85 238526 E02 5 CONSTRUCTION OF THE PRODUCT Figure 4 View to the opened KEMA 801A Ferrite cores spring loaded Mechanical interlock adjustable Figure 5 Side view...

Страница 10: ...79 mm Weight approx 5 5 kg Environmental classification Indoor use only Operating temperature 5 C to 40 C Relative humidity up to 80 Typical insertion loss in 50 system 0 0 10 20 40 30 60 50 0 1 1 10...

Страница 11: ...ries by the user 7 2 Cleaning The cleaning shall be done with dry cloth If a wed cleaning would become necessary make sure that no humidity gets inside the unit and clean the instrument housing with a...

Страница 12: ...rise Shanghai Co Ltd Beijing Branch T 8610 8526 2111 F 8610 8526 2141 chinasales teseq com Germany Teseq GmbH T 49 30 5659 8835 F 49 30 5659 8834 deinfo teseq ametek com Singapore AMETEK Singapore Pte...

Отзывы: